schmersal AZM 170 series Operating Instructions Manual

schmersal AZM 170 series Operating Instructions Manual

Solenoid interlock

Advertisement

Quick Links

Operating instructions
Solenoid interlock
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
EN
AZM 170 I
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM 170 series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM 170 series

  • Page 1 2.4 Technical data .........3 Further technical information can be found in the Schmersal 2.5 Safety classification .
  • Page 2 Operating instructions Solenoid interlock AZM 170 I 1.7 Exclusion of liability 2.2 Special versions We shall accept no liability for damages and malfunctions resulting from For special versions, which are not listed in the order code below 2.1, defective mounting or failure to comply with this operating instructions these specifications apply accordingly, provided that they correspond to manual.
  • Page 3 Operating instructions Solenoid interlock AZM 170 I 2.4 Technical data 3. Mounting Standards: IEC 60947-5-1, ISO 14119, BG-GS-ET-19 Enclosure: glass-fibre reinforced thermo- 3.1 General mounting instructions plastic, self-extinguishing Actuator and locking bolt: stainless steel 1.4301 On delivery, the actuator is in inserted condition. For Contact material: Silver power-to-unlock components, the actuator must be released...
  • Page 4 Operating instructions Solenoid interlock AZM 170 I 3.2 Dimensions AZM 170ST with connectors, 1x 4 poles, 1 x 8 poles All measurements in mm. AZM 170 with cut clamps and cable glands -2197 ¤ 18 ¤ 18 ø 4-10 Actuator M 20 Straight actuator B1 Angled actuator B5...
  • Page 5 Operating instructions Solenoid interlock AZM 170 I Mounting of the actuator 4. Electrical connection The marks on the used actuator opening of the solenoid 4.1 General information for electrical connection interlock and on the actuator must be opposite. The electrical connection may only be carried out by authorised personnel in a de-energised condition.
  • Page 6 Operating instructions Solenoid interlock AZM 170 I 4.2 Contact variants AZM 170 I with connector Contacts shown in a de-energised condition and with the actuator Power to unlock Power to lock inserted. 1 NO 1 NC 1 NO 1 NC AZM 170 I with cut clamps and screw terminals (ordering suffix -11) (ordering suffix -11)
  • Page 7 Operating instructions Solenoid interlock AZM 170 I AZM 170 I with connector 5. Set-up and maintenance Power to unlock Power to lock 5.1 Functional testing 1 NO 1 NC / 2 NC 1 NO 1 NC / 2 NC The safety function of the safety components must be tested. The (ordering suffix -11/02) (ordering suffix -11/02) following conditions must be previously checked and met:...
  • Page 8 Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone:...

This manual is also suitable for:

Azm 170 i

Table of Contents