3
Installation
● Ensure that the product is installed in an environment that meets the following conditions:
- Where excessive vibration is not present.
- On a sturdy surface. - On a level surface.
● When installing this product in an environment where waterproofing is required,
    be sure to properly waterproof the exposed nuts and bolts.
● Before use, be sure to read this manual as well as the instruction manual for the compatible PATLITE beacon.
SZ K -1 0 1
TYPE
● If using a cable gland, be sure that you are using it for the cable type beacons.
● Do not open unused mounting holes. If it is accidentally opened, be sure to waterproof the opening.
● Be sure to deburr after drilling.
● A cable gland with a mounting screw size of M16 x 20mm or less and cable size of 7 to 8mm is recommended.
Product Mounting with Knock-outs
Product Mounting Hole (2 holes)
(SF10-KT/SL10-KT)
□For Product Mounting Holes
 
Place the mounting bracket on a flat surface, with the bottom side up. Drill the holes from the bottom side.
Model
Drill
SF08-KT/SL08-KT
5mm
SF10-KT/SL10-KT
6mm
SF08-J/SL08-J/SKS
5mm
6mm
SF10-J/SL10-J/SKH
□For Cable Gland
Drill a 16 hole from the top surface.
 
Cable gland Installation
Product Mounting Hole (3 holes)
(SF10-J/SL10-J/SKH)
Number of Holes
2
2
3
3
Connect a commercially available cable gland
from the bottom of the Wall Mount Bracket.
Install and fix in place with nuts from above.
Notice
Caution
11
Cable gland Mounting Hole