  • Page 1 BP5F DA FI NO SV RU BEDIENUNGSANLEITUNG OPERATING MANUAL MANUEL D'UTILISATION...
  • Page 2: Table Of Contents

    The delivered product may vary Notes regarding the operating manual from product images. This document was created with Symbols all due care. Trotec accepts no liability whatsoever for possible mistakes or omissions. © Trotec Danger! Warns of a hazard which can lead to inju- ries.
  • Page 3: Safety

    The device must not be pointed at people. • The device is not a toy and does not belong in the Trotec accepts no liability for damages resulting from hands of children. improper use. In such a case, entitlements to a warranty are forfeited.
  • Page 4: Technical Data

    65 °C (150 °F): +1.5 % Emissivity 0.95 Distance to measuring spot ratio 20:1 Reaction time < 500 ms Power supply 9 V battery Switch off After approx. 20 seconds of non-use Operating manual - Food thermometer BP5F B - 3...
  • Page 5: Description Of The Device

    Description of the device The food thermometer BP5F detects the surface and inside temperature of foods by using an infrared sensor and a temperature probe. Beside the digital temperature display, three LEDs show whether the detected tempe- rature is within the HACCP range (Hazard Analysis and Critical Control Points).
  • Page 6 17. Red LED. Temperature between 4 °C and 60 °C (40 °F and 140 °F) 18. Green LED. Temperature below 4 °C (40 °F) 19. Measurement is on 20. Display is frozen Operating manual - Food thermometer BP5F B - 5...
  • Page 7: Operation

    (20) appears in the display. The last value to the surface or apply matt black paint with a very measured is shown. high and known level of emissivity. Operating manual - Food thermometer BP5F B - 6...
  • Page 8 4. Press and hold the "MODE" button (6) for 3 seconds for the measured values. to switch between seconds, minutes and hours. 5. Press the "TIMER" button (2) to set the correspon- ding value. Operating manual - Food thermometer BP5F B - 7...
  • Page 9: Maintenance And Repair

    Disinfect the temperature probe with a suitable disin- fectant. Repair Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer. Operating manual - Food thermometer BP5F B - 8...
  • Page 10: Disposal

    EC Low Voltage Directive 2006/95/EC, Annex III, Section B and the EC Directive 2004/108/EC about electromagnetic compatibility. We hereby declare that the food thermometer BP5F was de- signed, developed and produced in compliance with the named EC Directive.