Advertisement

INSTALLATION INSTRUCTIONS
General Wiring Diagram
Caution! Turn off electrical power at fuse or circuit breaker box before wiring luminaire to the power supply.
All luminaires must be individually connected to the AC power supply.
AC Input:
Product Dimensions
Installation: Electrical Connection
1. Loosen (8) M6 hex bolts of driver housing at torque value 6 N-m.
2. Connect the housing to suitable conduit (3/4" NPT).
3. Insert outside wires through conduit and the entry hole of the housing and connect to terminal block.
4. Introduce the wires of the branch circuit as following:
Black - Connect to line
White - Connect to Neutral
Green - Connect to Ground
5. Re-attach housing cover with the (8) M6 hex bolts to the driver housing cover and torque to 6 N-m.
6. Check to ensure tightness of conduit and driver housing cover.
LDPI, Inc. | (800)-854-0021 | www.ldpi-inc.com | sales@ldpi-inc.com
Black = Line
White = Neutral
Green = Ground
Black
Green
Terminal
White
Block
316mm
243mm
270mm
Dimming Control Wires: Gray (-)
LED Driver
230mm
Purple (0-10V input)
Yellow (+10V output)
( - ) ( + )
Lead wires
to LED load
316mm
243mm
287mm
270mm
LEHL2
Page 3
v.06.18.20