S+S Regeltechnik THERMASGARD RGTF1 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD RGTF1 Series Operating Instructions, Mounting & Installation

Duct / smoke gas temperature sensor, including mounting flange, with passive output
Table of Contents
  • Technische Daten
  • Caractéristiques Techniques
  • Montage Et Mise en Service
  • Технические Данные
  • Монтаж И Ввод В Эксплуатацию

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-2750-0000-1XX 27500-2020 V110 04 ⁄ 2020
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Kanal- ⁄ Rauchgas-Temperaturfühler, incl. Montageflansch,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Duct / smoke gas temperature sensor, including mounting flange,
with passive output
F
Notice d'instruction
Sonde de température de gaine ⁄ de gaz de fumées,
y compris bride de montage, avec sortie passive
r
Руководство по монтажу и обслуживанию
Канальный датчик дымовых газов, вкл. присоединительный фланец,
с пассивным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
RGTF 1 xx
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
RGTF 1
(IP 54)
RGTF 1 - KV
(IP 65)
RGTF 1 - Q
(IP 65)

Advertisement

Table of Contents
loading

Summary of Contents for S+S Regeltechnik THERMASGARD RGTF1 Series

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r RGTF 1 xx THERMASGARD ®  ø70 ~ 80 M20 x1.5 RGTF 1 xx Maßzeichnung Dimensional drawing ø70 ~ 80 Plan coté M20 x1.5 Габаритный чертеж ø70 ~ 80 ø70 ~ 80 RGTF 1 M20 x1.5 M20 x1.5 RGTF 1 - KV M20 x1.5 ø6...
  • Page 3: Technische Daten

    ® THERMASGARD RGTF 1 Rev. 2020 - V16 + ID Widerstandsthermometer ⁄ Rauchgastemperaturfühler THERMASGARD ® RGTF 1 mit passivem 1x Zweileiterschaltung Ausgang, mit Anschlusskopf aus Aluminium und geradem Schutzrohr, incl. Montageflansch. (Standard) Der Kanalfühler dient zur Erfassung von relativ hohen Temperaturen in gasförmigen Medien, z.B.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatur- sensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751)
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Achtung! Berücksichtigen Sie in jedem Fall die mechanischen und Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. thermischen Belastungsgrenzen der Schutzrohre nach DIN 43763 Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von bzw.
  • Page 6: Technical Data

    ® THERMASGARD RGTF 1 Rev. 2020 - V16 + ID Resistance thermometer ⁄ smoke gas temperature sensor THERMASGARD ® RGTF 1 with passive 1x two-wire connection output, with connecting head made from aluminium and straight protective tube, incl. mounting (Standard) flange.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Attention! In any case, please observe the mechanical and thermal only be connected to safety extra-low voltage. Consequential damages load limits of the protective tubes according to DIN 43763 or caused by a fault in this device are excluded from warranty or liability.
  • Page 9: Caractéristiques Techniques

    ® THERMASGARD RGTF 1 Rev. 2020 - V16 + ID Thermomètre à résistance/sonde de température de gaz de fumée THERMASGARD ® RGTF 1 avec 1x 2 fils sortie passive, tête de raccordement en aluminium et tube de protection droit, bride de montage (Standard) incluse.
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Page 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux conditions d’utilisa- Veillez à ne brancher l’appareil que sur un réseau de très basse tension tion réelles, notamment  : de sécurité.
  • Page 12: Технические Данные

    ® THERMASGARD RGTF 1 Rev. 2020 - V16 + ID Термометр сопротивления / датчик температуры дымовых газов THERMASGARD ® RGTF 1 с 1x Двухпроводное подключение пассивным выходом, с присоединительной головкой из алюминия и прямой защитной трубкой, (стандартно) вкл. присоединительный фланец. Канальный датчик предназначен для измерения относительно высоких...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14: Монтаж И Ввод В Эксплуатацию

    Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, должно осуществляться исключительно к безопасно малому напряжению. в особенности: Повреждения приборов вследствие несоблюдения упомянутых требований –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры Pt 100 Pt 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (KP10) 1.8 kOhm 10 kOhm 20 kOhm °...