D G F r
26000-2011 03 ⁄ 2011
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Raumtemperaturfühler und -messumformer,
Aufputz, Serie Frija I
G
Operating Instructions, Mounting & Installation
Room temperature sensors and measuring transducers,
on-wall, series Frija I
F
Notice d'instruction
Sonde et convertisseur de température d'ambiance,
en saillie, série Frija I
r
Руководство по монтажу и обслуживанию
Датчик температуры в помещении и преобразователь
температуры в помещении измерительный для
открытой установки, серия Frija I
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
RTF
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
RTF
RTF
mit Display
with display
avec écran
с дисплеем
RTF
(Edelstahl)
(stainless steel)
(acier inox)
(высококаче-
ственной стали)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Frija I Series and is the answer not in the manual?

Questions and answers

Summary of Contents for S+S Regeltechnik Frija I Series

  • Page 1 температуры в помещении измерительный для открытой установки, серия Frija I (Edelstahl) (stainless steel) (acier inox) (высококаче- ственной стали) S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Page 2 D G F r THERMASGARD ®  Gehäuse Frija I Maßzeichnung Enclosure Frija I Dimensional drawing boîtier Frija I Plan coté Корпус Frija I Габаритный чертеж Maßzeichnung Gehäuse Frija II Dimensional drawing Enclosure Frija II Plan coté boîtier Frija II Габаритный чертеж Корпус...
  • Page 3: Technische Daten

    ® THERMASGARD RTF 1 Raumtemperaturfühler THERMASGARD ® RTF 1 mit passivem Ausgang, wahlweise 1x Zweileiterschaltung RTF 1 mit ⁄ ohne Display zur Anzeige der Isttemperatur, in formschönen Gehäuse aus Standard Kunststoff, mit Schnapp deckel, Unterteil mit 4-Lochbefestigung, für Montage auf senkrecht oder waagerecht installierten UP- Dosen, mit Sollbruchstelle für Aufputz- anschluss oder in Gehäuse aus Edelstahl (Ober- und Unterteil sind aus Edelstahl, der Deckel ist geschraubt), vandalensichere Ausführung z.
  • Page 4 ® THERMASGARD RTF (diverse Ausführungen) RTFxxT Anschlussbild THERMASGARD ® RTF xx T Ausführung mit Fühler und Taster (max. 25 V= ⁄ 25 mA) (Frija I) RTFxxLT Anschlussbild ® THERMASGARD RTF xx LT Ausführung mit Fühler, Leuchtdiode (grün) und Taster (max. 25 V= ⁄ 25 mA) (Frija I) Anschlussbild RTFxxPT...
  • Page 5 ® THERMASGARD RTF (diverse Ausführungen) RTF xx PLT Anschlussbild ® THERMASGARD RTF xx PLT Ausführung mit Fühler, Potentiometer (1 kOhm), Leuchtdiode (grün) und Taster (max. 25 V= ⁄ 25 mA) (Frija I) RTFxxPW Anschlussbild ® THERMASGARD RTF xx PW Ausführung mit Fühler, Potentiometer (1 kOhm) und Wippschalter (Frija I)
  • Page 6 ® THERMASGARD RTF (diverse Ausführungen) RTF xx P Anschlussbild THERMASGARD ® RTF xx P (Frija I) Ausführung mit Fühler Standard und Potentiometer (1 kOhm) (Frija I) (Frija I) RTF xx P Display RTF xx U,U,P Schaltbild Schaltbild RTF xx U,U,P Display min.
  • Page 7 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 8 Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Hinweise zum mechanischen Ein- und Anbau: Anschluss der Geräte darf nur an Sicherheitskleinspannung erfol- Der Einbau hat unter Berücksichtigung der einschlägigen, für den gen. Folgeschäden, welche durch Fehler an diesem Gerät entste- Messort gültigen Vorschriften und Standards (wie z.
  • Page 9: Wichtige Hinweise

    Wichtige Hinweise Als AGB gelten ausschließlich unsere sowie die gültigen „Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektro industrie“ (ZVEI Bedingungen) zuzüglich der Ergänzungsklausel „Erweiterter Eigentumsvorbehalt“. Außerdem sind folgende Punkte zu beachten: – Vor der Installation und Inbetriebnahme ist diese Anleitung zu lesen und die alle darin gemachten Hinweise sind zu beachten! –...
  • Page 10: Technical Data

    ® THERMASGARD RTF 1 Room temperature sensor THERMASGARD ® RTF 1 with passive output, optional 1x two-wire connection RTF 1 with or without display for displaying the actual temperature in an elegant enclosure standard made of plastic, with snap-on lid, base with 4-hole attachment for installation on vertically or horizontally installed in-wall flush boxes, with predetermined breaking point for on-wall cable entry, or in enclosures made of stainless steel (top and bot- tom part are of stainless steel, the lid is screwed on), vandalism-secure version e.g.
  • Page 11 ® THERMASGARD RTF (diverse versions) RTFxxT Connecting diagram THERMASGARD ® RTF xx T Version with sensor and pushbutton (max. 25 V DC ⁄ 25 mA) (Frija I) RTFxxLT Connecting diagram THERMASGARD ® RTF xx LT Version with sensor, LED (green), and pushbutton (max.
  • Page 12 ® THERMASGARD RTF (diverse versions) RTF xx PLT Connecting diagram ® THERMASGARD RTF xx PLT Version with sensor, potentiometer (1kOhm), LED (green), and pushbutton (max. 25 V DC ⁄ 25 mA) (Frija I) RTFxxPW Connecting diagram ® THERMASGARD RTF xx PW Version with sensor, potentiometer (1kOhm), and rocker switch...
  • Page 13 ® THERMASGARD RTF (diverse versions) RTF xx P Connecting diagram THERMASGARD ® RTF xx P (Frija I) Version with sensor standard and potentiometer (1 kOhm) (Frija I) (Frija I) RTF xx P Display RTF xx U,U,P Connecting diagram Connecting diagram RTF xx U,U,P Display min.
  • Page 14 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 15 Mounting and Installation Devices are to be connected under dead-voltage condition. Devices Notes regarding mechanical mounting and attachment: must only be connected to safety extra-low voltage. Consequential Mounting shall take place while observing all relevant regulations and damages caused by a fault in this device are excluded from warranty standards applicable for the place of measurement or liability.
  • Page 16 General notes Our “General Terms and Conditions for Business“ together with the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry“ (ZVEI conditions) including supplementary clause “Extended Retention of Title“ apply as the exclusive terms and conditions. In additionIn addition, the following points are to be observed: –...
  • Page 17: Caractéristiques Techniques

    ® THERMASGARD RTF 1 Sonde de température d’ambiance THERMASGARD ® RTF 1 avec sortie passive, en 1 x 2 fils RTF 1 option sans ou avec écran pour afficher la température effective. Intégrée dans un Standard boîtier esthétique en matière plastique avec couvercle emboîté, partie inférieure avec 4 trous pour fixation sur boîtes d’encastrement montées verticalement ou horizontalement, avec point de rupture pour raccordement en saillie ou incorporée dans un boîtier en acier inox (partie supérieure et inférieure en acier inox, le cou-...
  • Page 18 ® THERMASGARD RTF (différents modèles) RTFxxT Schéma de raccordement THERMASGARD ® RTF xx T Modèle avec sonde et bouton-poussoir (max. 25 V= ⁄ 25 mA) (Frija I) RTFxxLT Schéma de raccordement ® THERMASGARD RTF xx LT Modèle avec sonde, diode électro luminescente (verte) et bouton-poussoir (max.
  • Page 19 ® THERMASGARD RTF (différents modèles) RTF xx PLT Schéma de raccordement ® THERMASGARD RTF xx PLT Modèle avec sonde, potentiomètre (1 kohm), diode électroluminescente (verte) et bouton-poussoir (max. 25 V= ⁄ 25 mA) (Frija I) RTFxxPW Schéma de raccordement ® THERMASGARD RTF xx PW Modèle avec sonde,...
  • Page 20 ® THERMASGARD RTF (différents modèles) RTF xx P Schéma de raccordement THERMASGARD ® RTF xx P (Frija I) Modèle avec sonde Standard et potentiomètre (1 kohm) (Frija I) (Frija I) RTF xx P écran RTF xx U,U,P Schéma de raccordement Schéma de raccordement RTF xx U,U,P écran min.
  • Page 21 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Page 22: Montage Et Installation

    Montage et installation Les raccordements électriques doivent être exécutés HORS TEN- Consignes pour l’installation mécanique : SION. Veillez à ne brancher l’appareil que sur un réseau de très Effectuer le montage en tenant compte des dispositions et règles basse tension de sécurité. Nous déclinons toute responsabilité ou standards à...
  • Page 23 Généralités Seules les CGV de la société S+S, les « Conditions générales de livraison du ZVEI pour produits et prestations de l’industrie électronique » ainsi que la clause complémentaire « Réserve de propriété étendue » s’appliquent à toutes les relations commerciales entre la société S+S et ses clients. Il convient en outre de respecter les points suivants : –...
  • Page 24: Технические Данные

    ® THERMASGARD RTF 1 Датчик температуры в помещении THERMASGARD ® RTF-1 с пассивным выходом, 1x Двухпроводное подключение RTF 1 на выбор – с дисплеем (для отображения измеренной температуры) или без дис- стандартное исполнение плея, в элегантном корпусе из пластика с защелкивающейся крышкой, низ с четырьмя...
  • Page 25 ® THERMASGARD RTF (различные исполнения) RTFxxT Схема соединения THERMASGARD ® RTF xx T Исполнение с датчиком и кнопкой (макс. 25 В пост. тока ⁄ 25 мА) (Frija I) RTFxxLT Схема соединения ® THERMASGARD RTF xx LT Исполнение с датчиком, светодиодом (зеленым) и...
  • Page 26 ® THERMASGARD RTF (различные исполнения) RTF xx PLT Схема соединения ® THERMASGARD RTF xx PLT Исполнение с датчиком, потенциометром (1 кОм), светодиодом (зеленым) и кнопкой (макс. 25 В пост. тока ⁄ 25 мА) (Frija I) RTFxxPW Схема соединения ® THERMASGARD RTF xx PW Исполнение...
  • Page 27 ® THERMASGARD RTF (различные исполнения) RTF xx P Схема соединения THERMASGARD ® RTF xx P (Frija I) Исполнение с датчиком стандартно и потенциометром (1 кОм) (Frija I) (Frija I) RTF xx P с дисплеем RTF xx U,U,P Схема соединения Схема соединения RTF xx U,U,P с...
  • Page 28 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассив- ные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 29: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Подклю- Указания к механическому монтажу: чение должно осуществляться исключительно к безопасно малому Монтаж должен осуществляться с учетом соответствующих, действи- напряжению. Повреждения приборов вследствие несоблюдения упо- тельных для места измерения предписаний и стандартов мянутых...
  • Page 30 Указания к продуктам В качестве Общих Коммерческих Условий имеют силу исключительно наши Условия, а также действительные «Общие условия поставки продукции и услуг для электрической промышленности» (ZVEI) включая дополнительную статью «Расширенное сохранение прав собственности». Помимо этого, следует учитывать следующие положения: – Перед установкой и вводом в эксплуатацию следует прочитать данное руководство; должны быть учтены все приведенные в нем указания! –...
  • Page 31 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 32 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры Temp. Pt100 Pt1000 Ni1000 Ni1000 Temp. TK5000 81-210 235Z °C Ω Ω Ω Ω Ω...