Multifan V-FloFan Installation Instructions Operating Instructions

Multifan V-FloFan Installation Instructions Operating Instructions

Hide thumbs Also See for V-FloFan:

Advertisement

V-FloFan
ENGLISH
Installation Instructions - Operating Instructions
IMPORTANT - READ CAREFULLY BEFORE USE
Document ID: INS00003-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V-FloFan and is the answer not in the manual?

Questions and answers

Summary of Contents for Multifan V-FloFan

  • Page 1 V-FloFan ENGLISH Installation Instructions - Operating Instructions IMPORTANT - READ CAREFULLY BEFORE USE Document ID: INS00003-B...
  • Page 2: Table Of Contents

    10 EU Declaration of Conformity ............ 11 General warning symbol Glossary .................... 12 Warning for electricity Introduction Thank you for choosing this V-FloFan. Warning for hot surfaces IMPORTANT: READ THESE INSTRUCTIONS CAREFULLY BEFORE USE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Warning for automatic activation...
  • Page 3: Information

    • operate the fan. Identification of the product • monitor the correct operation of the fan. A rating plate is permanently attached to the V-FloFan. Do not remove the rating plate. Maintenance personnel The rating plate displays electrical, mechanical and identification information.
  • Page 4 V-FloFan Explanation type plates Article number VV Drip proof µ At optimum Serial number IP class Static pressure (0 Pa) Wiring diagram Insulation class Air volume at 0 Pa (m Voltage (V) TEAO (Totally Enclosed Air Over) Static pressure (x Pa)
  • Page 5: Intended Use

    Illustration 2: VFloFan operating principle Never install a damaged or incomplete fan. This V-FloFan is intended for the destratification of air or the circulation of • It is the responsibility of the installer that the installation is done in ac- air. This V-FloFan creates vertical air movement with a very low air speed.
  • Page 6: Mechanical

    Mechanical Installation position Illustration 4: V-FloFan installation position Illustration 6: V-FloFan optional bracket for greenhouses A maximum 5m (16ft) for best results B ± 18m (59ft) for best results 6 | ENGLISH Original instructions...
  • Page 7: Electrical

    WARNING Do not mount the fan using chains, rope, steel cable or similar. N / L2 The V-FloFan will spin and/or sway. Guarding Illustration 10: 1~ (North America) This fan is default supplied with a guard at the bottom (intake) side. This fan is intended to be installed at such a height where a guard at the top (exhaust) side is usually not required.
  • Page 8: Thermal Protection

    V-FloFan WARNING If the unexpected start of the motor by the thermostat can cause a hazard or is prohibited by local regulations, the ther- mostat must be connected into a control circuit that will not al- low the motor to restart until the circuit is manually reset.
  • Page 9: Commissioning

    V-FloFan For US only: NOTICE For 3~ fans only: The V-FloFan is very susceptible to other airflows that can dis- WARNING rupt a good functioning: Do not use horizontal airflow fans at the same time as when the To Reduce The Risk of Fire or Electric Shock, Do Not Use This V-FloFan is in operation.
  • Page 10: Maintenance Subjects

    V-FloFan ► Maintenance tasks – TO BE CARRIED OUT ANNUALLY Bearings 1. Only for 1~ fan motors: check the capacitor capacitance. The bearings used in the fan and/or fan motor are maintenance free and greased for life. Average lifespan during normal operation is >30.000 hours.
  • Page 11: End Of Life

    Other air currents influence the airflow pattern Check if all windows and doors are closed Check is other air currents affect the operation of the V-FloFan , optionally by means of a smoke gen- erator. Use original spare parts only.
  • Page 12: Glossary

    V-FloFan T4E40, T6E40 Explosive atmosphere and ending with: 60 A mixture of air, under atmospheric conditions, with flammable sub- stances in the form of gases, vapours, mists or dusts in which, after igni- are in conformity with the relevant Union harmonisation legislation and fulfil all tion has occurred, combustion spreads to the entire unburned mixture.
  • Page 16 is a brand of Vostermans Ventilation B.V. 00/0000 Venlo - The Netherlands Bloomington, IL- USA Tmn Klang Jaya - Malaysia Shanghai - China Tel. +31 (0)77 389 32 32 Tel. +1 309 827-9798 Tel. +60 (0)3 3324 3638 Tel. +86 21 5290 2889/2899 ventilation@vostermans.com ventilation@vostermansusa.com ventilation@vostermansasia.com...