Meter Properties And Functions; Important User Information; Safety Instructions; Liability - Elis FLONET FH30 Series Project Design, Installation And Service Manual

Electromagnetic flowmeter
Table of Contents

Advertisement

ELIS PLZEŇ a. s.
1.3

Meter properties and functions

The functions of the meter transmitter include visualisation of the measured values and, using the
associated control push-buttons, setting of the operational meter parameters.
Main flowmeter functions:
• Bi-directional measurements of:
o
volume flow rate;
o
aggregate fluid volume passed through the meter sensor;
Archiving of the measured data and information on specific operational events;
Checking on sensor flooding condition.
Flowmeter interface facilities:
o
Two binary outputs, one current output
o
Communication interface RS-485 MODBUS RTU
1.4

Important user information

Electromagnetic flowmeters of the FLONET FH30xx type series are manufactured and tested in
accordance with the applicable international regulations and standards. To ensure successful meter
commissioning and meeting the specified metrological parameters, the user shall duly observe all
directions and recommendations given in the product manual.

1.4.1 Safety instructions

Prior to any meter handling, the user and/or the meter installation staff shall get acquainted with the
meter documentation.
When connecting the flowmeter to the power supply, due attention shall be paid to the applicable
national regulations and standards with special regard to the issues of labour safety and health
protection.
The meter installation, electrical connection and commissioning work shall be performed by suitably
qualified operators.
It is essential to observe all conditions and instructions given in the product manual regarding the
meter installation and electrical connection, and to pay due attention to all warning labels.
Should the product show signs of incorrect function, the user shall not attempt to dismantle the
meter. Any repair work is reserved to the meter manufacturer or their duly authorised partners.
When sending a meter for repair, make sure to attach representation on decontamination as of
Chapter 17 (ANNEX) hereof (see page 71).
The key meter parts are protected against dismantling by company seals. Should any such seal be
broken, the customer will forfeit their right to claim free warranty services.

1.4.2 Liability

ELIS PLZEŇ a.s., the manufacturer of flowmeters for liquids, delivers its products in the highest possible
quality. All products developed by ELIS PLZEŇ are part of intellectual property of the company and are
a subject of copyrights. The same rights also apply to the documents delivered together with the product.
It is forbidden to supplement, amend or otherwise alter documents without prior consent of ELIS PLZEŇ
a.s. Any infringement of the aforementioned intellectual property is punishable.
The documents delivered with the product are meant for familiarizing with the product itself and with the
conditions of its use and installation. All flowmeter users are obliged to get familiar in detail with these
ELIS PLZEŇ a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, phone.: +420 377 517 711, fax: +420 377 517 722 Es 90678K
Project design, installation and service manual
Electromagnetic flowmeter FLONET FH30xx
Page 6 of 72