Dometic 10 Series Installation Manual page 15

Compressor refrigerator
Hide thumbs Also See for 10 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
RC(S)(L)(D)10-Series
Refrigerator depth (C)
(excludes control knob
5 mm)
Recess height (H)
Recess width (W)
Recess depth (D)
3.2
Installing the condensation drain
I
NOTE
• Condensation can form inside the refrigerator due to frequent door
opening, incorrectly stored food or food that is stored when it is too
warm.
• Condensation must be drained with a constant slope.
Install the condensation drain as follows:
➤ Run the condensation hose from the refrigerator through an opening in the floor
which goes outside.
3.3
Connecting the power supply
A
NOTICE!
• The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable national regulations and
standards.
• To avoid voltage loss and therefore a drop in performance, the cable
should be kept as short as possible and should not be interrupted if
possible. For this reason avoid additional switches, plugs or power
strips.
• Before connecting check whether the operating voltage and the
battery voltage correspond (see type plate).
➤ Determine the required cross section of the cable in relation to the cable length
according to fig. 4, page 5.
➤ Connect the cables to the AMP connector of the refrigerator (fig. 5, page 6).
➤ Connect the other ends of the cables to the
EN
RCS10.5(S)(T)
555 mm
824 mm
528 mm
558 mm
12 Vg
Installing the refrigerator
RCS10.5X(S)(T)
610 mm
824 mm
528 mm
613 mm
power supply:
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents