Release the calibration button when
4.
the
totaliser
followed by the version number on the
lower line of the display.
5. The lower line will show the following
in a looping sequence:
1 PULSE CHANNEL - Single channel
pulser connected
2 PULSE CHANNEL - Two channel
pulser connected
REED PULSER - Reed switch pulser
connected
Press calibration button once when desired option is displayed.
Select 2 PULSE CHANNEL for Weights & Measures Alpha, REED
PULSER for Alpha fitted with PULS.E18 reed switch pulser (pre August
2003) or Adblue Alpha and 1 PULSE CHANNEL for all other Alpha
versions.
6. The lower line will show the following
in a looping sequence:
LITRES – Display measures in litres.
GALLONS – Display measures in
gallons (Imperial or US)
Press calibration button once when
desired option is displayed.
7. The lower line will show the following
in a looping sequence:
BACKLIGHT ON – backlight on
constantly.
BACKLIGHT OFF – backlight off.
ON FOR FUELLING – backlight only
on during fuelling.
Press calibration button once when
desired option is displayed.
display shows
00000.0
VER
CALIB
VER 4.00
00000.0
CALIB
1 PULSE CHANNEL
00000.0
CALIB
00000.0
CALIB
BACKLIGHT ON
LITRES
S709/8