Wordclock Connections & Termination
For correct operation it is essential that the wordclock cabling be terminated correctly. The
03D has a wordclock termination ON/OFF (75 ) switch on the rear panel. Wordclock is a
TTL signal, and IN and OUT connections use BNC connectors. Three wordclock
distribution examples are shown below. Note the 75 wordclock terminator switch
settings.
1. Parallel Distribution Box
WORDCLOCK IN
75
Switch=ON
03D-A
In this example, a parallel distribution box is used to distribute the wordclock signal among
devices. All wordclock terminator switches are set to ON.
2. Using BNC T-bar Connectors
WORDCLOCK
OUT
WORDCLOCK IN
75
Switch=OFF
03D-A
This example is similar to the above except that T-bar connectors are used. In this system,
only the last device's wordclock terminator switch is set to ON.
3. Daisy Chain Distribution
In this example, the wordclock master is a digital multitrack recorder. Both 03D wordclock
terminator switches are set to ON. This method of wordclock distribution is not
recommended for large systems.
WORDCLOCK
Distribution box
OUT
WORDCLOCK IN
WORDCLOCK IN
75
Switch=ON
75
Switch=ON
Other
03D-B
Device-A
WORDCLOCK IN
WORDCLOCK IN
75
Switch=OFF
75
Switch=OFF
Other
03D-B
Device-A
WORDCLOCK
OUT
IN
OUT
IN
WORDCLOCK
WORDCLOCK
75
Switch=ON
75
Switch=ON
03D-A
03D-B
03D Applications 59
WORDCLOCK IN
75
Switch=ON
Other
Device-B
WORDCLOCK IN
75
Switch=ON
Other
Device-B
OUT
Yamaha 02R & 03D Applications Guide