Page 1
Fastrack VS Verion 1.0 and later YAMAHA 03D SERIAL AUDIO MIXER The Fastrack VS hybrid editing system interfaces to the 03D Serial Audio Mixer with a 6-pin DIN to 9-pin RS-422 serial control cable and Yamaha 03D audio mixer serial protocol. The 03D must contain the optional “03D VEK for Video Editing”...
PS-2 plug Mixer Setup ESAM II protocol is an option to the 03D Mixer and needs to be installed at the Yamaha factory or customer installed using a serial terminal. Consult with your Yamaha representative. 1. Connect the serial control cable from a Fastrack VS "COM" port to the 6-pin “TO HOST” serial port on the rear of the 03D console.
Page 3
Analog inputs 9-16 use 1/4" TRS (tip/ring/sleeve) connections. Monitor outs uses 1/4" TRS connections. Bus outs use 1/4" TRS connections. ST Out uses XLR and is the PROGRAM OUT to any/all record channels. Page 3 of 7 09/24/2002 Fastrack VS and the Yamaha 03D Audio Mixer...
Page 4
Editware Technical Note MONITORING The 03D has a monitoring bus that can be remotely controlled as a preview bus; therefore, all audio previews should be done utilizing this preview switcher in the 03D. Set each source's BUS Out and monitoring in the [PAN/ROUTE] section as below for four channels...
Page 5
Note: Track 8 is not in use, hence the audio crosspoints of 1, 2, 3 are not conflicting Assign the following audio cross-points in the Source Assignment page [SHIFT]+[ASGN] in Fastrack VS for the 03D setup (two channels per device): Page 5 of 7 09/24/2002 Fastrack VS and the Yamaha 03D Audio Mixer...
Page 6
Shift INIT brings up the Settings window. Lines 25 through 28 are for Audio Mixer configuration. The Values (third column) need to be set as below for Yamaha 03D control. Line 25 (Type) will consist of a drop down menu, chose YAMAHAHOST. Line 26 needs to be filled in manually (COM8 shown here, your port number may vary.
Page 7
Yamaha 03D Audio Mixer Control Panel Note: The 03D ST OUT is used for monitoring (VU meters active) and Program Output. Ensure the ST fader is up to 0 level, the ST ON lamp is illuminated, and the MONITOR OUT button is in the UP position.