SCHURTER 0104U Series Manual

SCHURTER 0104U Series Manual

Advertisement

1. Wiring for 0104U

1. Wiring for 0104U
Cable Clamp
Cable Clamp
(turn for Ø < 6.85 mm)
(turn for Ø < 6.85 mm)
Torque Value
Torque Value
0.8Nm
0.8Nm

Applicable Cable Types

Applicable Cable Types
IEC
IEC
Type
Type
Cable Type
Cable Type
H05VV -F 3G
H05VV -F 3G
0104U
0104U
H05RR -F 3G
H05RR -F 3G
UL
UL
Type
Type
Cable Type
Cable Type
SV...
SV...
0104U
0104U
SJ...
SJ...
1) Harmonized wire coding in accordance with IEC60227-5 respectively IEC60245-4.
1) Harmonized wire coding in accordance with IEC60227-5 respectively IEC60245-4.
2) If cord has a length exceeding 2m, nominal cross-sectional areas shall be 1.5mm
2) If cord has a length exceeding 2m, nominal cross-sectional areas shall be 1.5mm
3) Types according to UL 62 which begins with the given letters (i.e. SV... includes SV, SVT, SVE etc.).
3) Types according to UL 62 which begins with the given letters (i.e. SV... includes SV, SVT, SVE etc.).
4) The maximum wire size depends on the maximum cable diameter and on the standard of the cable type used.
4) The maximum wire size depends on the maximum cable diameter and on the standard of the cable type used.
Engineering Documentation
owner
creation date
vettersa
06.12.2017
30
30
7
7
Cable end sleeves
Cable end sleeves
(Optional, not enclosed)
(Optional, not enclosed)
Torque Value
Torque Value
0.4Nm
0.4Nm
N
N
blue
blue
Yellow /
Yellow /
green
green
L
L
brown
brown
1)
1)
Wire Size
Wire Size
2)
2)
min.
min.
max.
max.
2
2
3x 1.00 mm
3x 1.00 mm
3x 1.50 mm
3x 1.50 mm
2
2
3x 1.00 mm
3x 1.00 mm
3x 1.50 mm
3x 1.50 mm
3)
3)
Wire Size
Wire Size
min.
min.
max.
max.
3x AWG 18
3x AWG 18
3x AWG 16
3x AWG 16
3x AWG 18
3x AWG 18
3x AWG 14
3x AWG 14
release date
released by
30.04.2018
vettersa
0104U-X1XX-XX:
0104U-X1XX-XX:
cut for cables
cut for cables
over Ø 8.5 mm
over Ø 8.5 mm
Cable guard
Cable guard
N
N
IN
IN
PE
PE
L
L
Cable Ø
Cable Ø
4)
4)
max.
max.
2
2
10.5mm
10.5mm
2
2
10.4mm
10.4mm
Cable Ø
Cable Ø
4)
4)
max.
max.
10.5mm
10.5mm
10.5mm
10.5mm
2
2
or more.
or more.
Mounting Instruction for 0104U
change order no
rev
page
2015283
B
1 of 2
N'
N'
PE'
PE'
OUT
OUT
L'
L'
Torque Value
Torque Value
0.5Nm
0.5Nm
0115.0071

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0104U Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SCHURTER 0104U Series

  • Page 1 1. Wiring for 0104U 1. Wiring for 0104U Cable Clamp Cable Clamp 0104U-X1XX-XX: 0104U-X1XX-XX: (turn for Ø < 6.85 mm) (turn for Ø < 6.85 mm) cut for cables cut for cables over Ø 8.5 mm over Ø 8.5 mm Cable guard Cable guard Cable end sleeves...
  • Page 2 2. . Assembly Instruction 2. . Assembly Instruction Disconnect power before wiring. Disconnect power before wiring. Keep removed piece parts at a safe place to have them ready for reassembling. Keep removed piece parts at a safe place to have them ready for reassembling. 1.

Table of Contents