ABB ACS880-01 Application Manual page 32

Atex-certified safe disconnection function, ex ii 2 gd for drives option +q971
Hide thumbs Also See for ACS880-01:
Table of Contents

Advertisement

32 Parameter settings
Index
Name
SS1.14
SS1-t delay for STO
SAR1 ramp settings
200.112
SAR1 ramp time to
zero
200.202
SAR speed scaling
SARx.02
SAR initial allowed
range
SARx.21
SAR1 min ramp time
to zero
SARx.22
SAR1 max ramp time
to zero
Example value
Description
20000 ms
Sets the monitoring delay after which the FSO module
activates the drive STO and SBC at the latest, if the
motor speed has not gone below the zero speed limit
(parameter
Time monitoring: This value sets the security delay that
the FSO module monitors. Adjust the default value
when necessary.
Ramp monitoring: This value has no effect in the oper-
ation.
2000 ms
Sets the target time for the stop ramp SAR1 that is used
in the SS1 and function. Adjust the default value when
necessary.
The target time is the time in which the drive deceler-
ates the motor from the speed defined by parameter
200.202
Note: With value 0 ms, the drive uses the emergency
stop ramp set by drive parameter 23.23 (see section
SS1 ramp parameters in the drive/inverter
unit (page
monitors the actual ramp (ramp monitoring or time
monitoring).
1500 rpm
Sets a speed value that the FSO module uses as a
reference point in ramp parameter calculations (see
SAR1 ramp parameters 200.112, SARx.21,
and SARx.02.). Adjust the default value when neces-
sary.
100 ms
Sets the initial allowed range for the SAR0/SAR1 ramp.
This parameter moves the location of the maximum
monitoring ramp forward on the time axis, when monit-
oring is started. The slope of the ramp stays the same
as defined with parameters
more information, see the FSO module user's manual.
Time monitoring: This value has no effect in the opera-
tion.
Ramp monitoring: Adjust the default value when neces-
sary.
1000 ms
Sets the minimum ramp time for the SAR1 ramp monit-
oring.
Time monitoring: This value has no effect in the opera-
tion.
Ramp monitoring: Sets the minimum stop ramp time
for the emergency stop. Adjust the default value when
necessary.
Note: With value 0 ms, the minimum ramp is not mon-
itored.
3000 ms
Sets the maximum ramp time for the SAR1 ramp
monitoring.
Time monitoring: This value has no effect in the opera-
tion.
Ramp monitoring: Sets the maximum stop ramp time
for the emergency stop. Adjust the default value when
necessary.
FSOGEN.51
or FSOGEN.52) yet.
to zero.
33)). Also in this case, the FSO module only
200.202
SARx.22
and SARx.22. For