INTRODUCTION If the QSI electronics are used in a manner not specified by the The QSI communications manufacturer, the protection provided module is a multiple capability by the equipment may be impaired. electronics package. The module is available with the plain cover GENERAL INFORMATION plate or the display mount cover plate.
INSTALLATION To mount your QSI module (with or without a display) to a QSE meter: CAUTION: Installation near • Install the cover plate seal. high electromagnetic fields and high current fields is not • Connect the QSI module PC recommended and may result board connector to the AFE in inaccurate readings.
WIRING ISOLATED POWER SUPPLY WIRING All electronic options are associated with a matching style of meter The QSE meter has an internal cover plate. This cover plate has connection to the conductive fluid four threaded ports, compatible through one of the electrodes. with PG7 threads, for gaining wiring The fluid and/or plumbing in most access to the electronics inside the...
QSI2 WIRING QSI VERSION 2 PC BOARD Pulse In 10-Pin Ribbon Connector RTDs Pulse Out Power In Figure 6 WIRING DIAGRAM ISOLATED PWR SUPPLY Inputs: Temp Sensors, GPI Custom Sensor 12-30VAC, 50-60Hz Outputs: Pulse Output / 12-36VDC QSI Version 2 Power (-) Power (+) 10-Pin...
To learn how to get started strain reliefs (black), installed on using the FLOMEC App, visit: the meter at the factory, will allow. Therefore, (2) reduced fit strain reliefs (gray) are included with the probes.
After wiring the probes to the During normal system operation, correct terminal of the PC board, probe PT100 #1 is installed at the perform the differential check. meter outlet end and probe PT100 #2 is installed in the system supply line.
MAINTENANCE • Remove and replace the coin cell battery (CR2032) on the back Check cable-entry seals periodically. side of PC board (see Figure 14). Tighten and/or apply sealant if NOTE: To maintain certifications, a needed. This is especially important UL approved battery must be used. in environments containing heavy concentrations of dust, •...
SPECIFICATIONS MECHANICAL ELECTRICAL Pollution Female 1/2-20 UNF-2B Cover Plate (Compatible with Degree Port Threads PG7 thread) Installation Port Strain Category Hubble PG7 Relief Altitude 2000m Max. 0.11”-0.26” Grip Range Indoor use only (2.79 - 6.6mm) OUTPUTS & COMMUNICATION Operation +32°F to +140°F QSI Version 1: Temperature (0°C to +60°C)
SERVICE The Waste Electrical and Electronic Equipment (WEEE) directive For warranty consideration, contact (2002/96/EC) was approved by the your local distributor. If you need European Parliament and the Council further assistance, contact the GPI of the European Union in 2003. This symbol indicates that this product Customer Service Department at: contains electrical and electronic...