Download Print this page

Flomec QSI Series Installation Instructions Manual

Electronics to g-series meter adapter kit

Advertisement

Quick Links

Adapter Kit - QSI Electronics to G-Series Meter
Installation Instructions
These installation instructions cover
the adapter kit installation of the QSI1,
QSI2 and QSI3 versions of communi-
cations electronics to G-Series Meters.
The instructions are the same for QSI
versions with or without a display.
Check the contents of your kit using
the list below as a reference. Make
sure the power to your G-Series
meter is disconnected.
INSTRUCTIONS
1. Remove any attached products
from the 1" male NPT fitting on
top of your G-Series meter. It will
be replaced with the adapter kit
components.
2. Remove the (6) #8-16 x 3/4
screws attaching the kit cover
plate to the adapter and separate.
Do not damage the seal between
the two components (
3. Screw the kit elbow adapter onto
the 1" NPT fitting on top of your
G-Series meter, aligning the face
of the adapter (still attached to
the elbow) in desired direction.
4. Make sure the seal is in place on
the face of the adapter prior to
routing the wiring from the meter.
5. Route the (2) wires from the meter
sensor through the elbow adapter
and out the face of the adapter.
Snip ends to remove stripped
wire. Connect either of the meter
sensor wires to either wire from
the QSI PC board using the
enclosed butt-splice connectors
(see Figure 1). Crimp connector
to splice wires and release
10/2016
6. To route external power and/or
).
see Figure 1
7. Make sure the power is
8. Connect cable wires to the QSI
9. Mount the cover plate on the
insulation gel. Repeat with the
remaining sensor and PC board
wire. See wiring diagram in these
instructions.
electronic cables to the QSI PC
board screw terminals, prepare
the cover plate by removing the
mushroom plug from each strain
relief you intend to use. The strain
relief will accommodate cable
sizes of 0.11" (0.28 cm) through
0.26" (0.66 cm) diameter.
disconnected from external
cables before beginning this
step. Route external cables
through the strain reliefs, and then
tighten the dome nut securely
around the cable to provide an
environmental seal.
PC board screw terminals per
the wiring diagram in these
instructions.
adapter making sure the seal
is seated properly between
them. Replace the (6) previously
removed screws to secure
the cover plate to the adapter.
Tighten screws.
920897-03 Rev-

Advertisement

loading

Summary of Contents for Flomec QSI Series

  • Page 1 Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communi- cations electronics to G-Series Meters. The instructions are the same for QSI versions with or without a display. Check the contents of your kit using the list below as a reference.
  • Page 2 ELBOW ADAPTER O-RING ADAPTER SEAL MUSHROOM PLUGS (4) (4) M5-0.8 X 12 SCREW COVER PLATE Q09 DISPLAY (SHOWN) (OR) NO DISIPLAY (6) SCREWS, #8-16 X 3/4 (2) WIRES FROM QSI PC BOARD. NON-POLARIZED 1-11 1/2 NPT FEMALE THREAD R2 UR2-D UY2 UY2-D UP2 UP3 UCC UPC UR2 UR2-D UY2 UY2-D UP2 UP3 UCC UPC UR2 UR2-D UY2 UY2-D UP2 UP3 UCC UPC Crimp with cap...
  • Page 3: Power Input

    TERMINAL CONNECTIONS CHART PT100-Red PT100-White Sensor #1 PT100-Blue PT100-Red GPI Sensor PT100-White Sensor #2 PT100-Blue RS-485 + Coil A RS-485 - Coil B Pulse Output RS-485 GND RS-485 Pulse Input Power 4-20mA Figure 2 TEMP SENSOR TEMP SENSOR Low level sine wave Low level sine wave Coil A Coil A...
  • Page 4: Wiring Diagram

    WIRING DIAGRAMS QSI VERSION 1 PC BOARD RS-485 RTDs RS-485 Pulse Out Power In Coil A & B (Non-polarized wires) Figure 3 WIRING DIAGRAM ISOLATED POWER Inputs: Temp Sensors, Variable Reluctance, Pickup Coil SUPPLY Outputs: RS-485, Pulse Output 12-36V AC/DC QSI Version 1 Power (-) Pulse Out (+)
  • Page 5 WIRING DIAGRAMS QSI VERSION 2 PC BOARD Pulse In RTDs Coil A & B (Non-polarized wires) Pulse Out Power In Figure 5 WIRING DIAGRAM ISOLATED POWER Input: Temp Sensors, Variable Reluctance, Pickup Coil SUPPLY Output: Pulse Output 12-36V AC/DC QSI Version 2 Power (-) Power (+) Customer...
  • Page 6 WIRING DIAGRAMS QSI VERSION 3 PC BOARD 4-20mA Coil A & B (Non-polarized wires) Pulse Out Power In 4-20mA Figure 7 WIRING DIAGRAM - 4-20mA and Pulse Outputs Customer Equipment with Built-in Power Supply Inputs: Standard Remote Sensor (Variable Reluctance Pickup Coil) Outputs: Customer Equipment, 4-20mA Sensing, Built-in Loop Power Supply Inputs Isolated Outputs...
  • Page 7 Recommended maximum cable length - 20ft. WIRING DIAGRAMS WIRING DIAGRAM Customer Equipment without Built-in Power Supply - 4-20mA Output with Separate Power Supply ISOLATED QSI Version 3 POWER SUPPLY 12-36V AC/DC Customer Power (-) Equipment Power (+) 4-20mA (+) (Current) Loop (-) 4-20mA (-) (Current)
  • Page 8 © 2016 Great Plains Industries, Inc., All Rights Reserved. Great Plains Industries, Inc. / 888-996-3837 / GPI.net 10/2016 920897-03 Rev-...

This manual is also suitable for:

Qsi1Qsi2Qsi3