Adapter Kit - QSI Electronics to OM Meter
Installation Instructions
These installation instructions
cover the adapter kit installation of
the QSI1, QSI2 and QSI3 versions
of communications electronics to
OM Meters. The instructions are
the same for QSI versions with
or without a display. Check the
contents of your kit using the list
below as a reference. Make sure
the power to your OM meter is
disconnected.
INSTRUCTIONS
1. Remove the circular plate (or
other product) from the top
of your OM meter. It will be
replaced with the adapter kit
components.
2. Remove the (6) #8-16 x 3/4
screws attaching the kit cover
plate to the adapter and separate.
Do not damage the seal between
the two components (see Figure
2).
3. Install the O-ring received with
the kit in the O-ring gland on the
bottom of the adapter; mount
the adapter to the OM meter and
secure with (4) metric screws
provided with the kit. Tighten
screws.
4. Make sure the seal is in place on
top of the adapter prior to routing
the wiring from the meter.
5. Route the wiring from the meter
up through the adapter and
connect the wires to the QSI
PC board screw connectors,
per the wiring diagram in these
instructions.
10/2016
6. To route external power and/or
electronic cables to the QSI PC
board screw connectors, prepare
the cover plate by removing the
mushroom plug from each strain
relief you intend to use. The strain
relief will accommodate cable
sizes of 0.11" (0.28 cm) through
0.26" (0.66 cm) diameter.
7. Make sure the power is
disconnected from external
cables before beginning this step.
Route external cables through the
strain relief(s), and then tighten
the dome nut securely around the
cable to provide an environmental
seal.
8. Connect cable wires to the QSI
PC board screw connectors
per the wiring diagram in these
instructions.
9. Mount the cover plate on the
adapter making sure the seal
is seated properly between
them. Replace the (6) previously
removed screws to secure the
cover plate to the adapter.
Tighten screws.
920897-01 Rev-

Advertisement

loading

Summary of Contents for Flomec QSI Series

  • Page 1 Adapter Kit - QSI Electronics to OM Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics to OM Meters. The instructions are the same for QSI versions with or without a display.
  • Page 2 (6) SCREWS, #8-16 X 3/4 COVER PLATE Q09 DISPLAY (SHOWN) (OR) NO DISIPLAY (4) MUSHROOM PLUGS (4) M5-0.8 X 12 SCREW SEAL O-RING GLAND ADAPTER O-RING Figure 1 KIT CONTENTS • (1) Completely assembled QSI • (1) Instruction sheet. module (with or without a display). •...
  • Page 3: Power Input

    TERMINAL CONNECTIONS CHART PT100-Red PT100-White Sensor #1 PT100-Blue PT100-Red GPI Sensor PT100-White Sensor #2 PT100-Blue RS-485 + Coil A RS-485 - Coil B Pulse Output RS-485 GND RS-485 Pulse Input Power 4-20mA Figure 2 TEMP SENSOR Low level sine wave Coil A input PT100-Red...
  • Page 4: Wiring Diagram

    WIRING DIAGRAMS QSI VERSION 1 PC BOARD RS-485 RTDs RS-485 Pulse Out Pulse Input Power In Figure 3 WIRING DIAGRAM ISOLATED POWER Inputs: Temp Sensors, Pulse Input SUPPLY Outputs: RS-485, Pulse Output 12-36V AC/DC QSI Version 1 Power (-) Pulse Out (+) Open Collector Pulse Input Power (+)
  • Page 5 WIRING DIAGRAMS Connection / Wiring Diagram Standard Pulse Output Board Pull Up Pulse Pulse In - Pulse In + Resistor Input Pulse In + Pulse In - Not Both Figure 5 Connection / Wiring Diagram Reed Only Pulse Output Board Pulse In + Pulse In - (Recommended, but not required)
  • Page 6 WIRING DIAGRAMS QSI VERSION 2 PC BOARD Pulse In RTDs Pulse Out Pulse Input Power In Figure 7 WIRING DIAGRAM ISOLATED POWER Inputs: Temp Sensors, Pulse Input SUPPLY Outputs: Pulse Output 12-36V AC/DC QSI Version 2 Power (-) Power (+) Customer OM Meter Equipment...
  • Page 7 WIRING DIAGRAMS QSI VERSION 3 PC BOARD 4-20mA Pulse Out Pulse Input Power In 4-20mA Figure 9 WIRING DIAGRAM - Digital Pulse Input - 4-20mA and Pulse Outputs Customer Equipment with Built-in Power Supply Inputs: OM or Conditioned Signal Sensor (Open Collector) Outputs: Customer Equipment, 4-20mA Sensing, Built-in Loop Power Supply Inputs Isolated Outputs...
  • Page 8 Use R = 10k (10000 ohms) for distance up to 50 ft. Use R = 5.1k (5100 ohms) for distance up to 100 ft. Use R = 2.7k (2700 ohms) for distance up to 250 ft. Pulse WIRING DIAGRAMS Do not use R less than 2.4k (2400 ohms) Input 4-20mA...

This manual is also suitable for:

Qsi1Qsi2Qsi3