Lhcs4X00_Typeput; Lhcs4X00_Typerackdataput; Lhcs4X00_Typecyclicdataout; Lhcs4X00_Typecimdataout - Siemens SIPLUS HCS4 00 Series Configuration

Heating control in tia portal
Table of Contents

Advertisement

4 Mode of Operation
4.2 PLC data types
4.2.7

"LHcs4x00_typePut"

PLC data type "LHcs4x00_typePut" contains data to be written for the HCS4x00
heating control systems.
Table 4-7
Name
Data type
hcs
Array[1..n] of

"LHcs4x00_typeRackDataPut"

"LHcs4x00_typeRackDataPut"
4.2.8
The "LHcs4x00_typeRackDataPut" data type includes the entries for the configured
HCS4x00 heating control system.
Table 4-8
Name
io
"LHcs4x00_typeHwDataIn"
cyclicData

"LHcs4x00_typeCyclicDataOut"

datasets
"LHcs4x00_typeDataset"
4.2.9
"LHcs4x00_typeCyclicDataOut"
PLC data type "LHcs4x00_typeProcessDataOut" contains the cyclic output data for
the configured HCS4x00.
Table 4-9
Name
Data type
cim

"LHcs4x00_typeCimDataOut"

pm
"LHcs4x00_typePmDataOut"
pom
Array[1..24] of
"LHcs4x00_typePomDataInOut"
4.2.10
"LHcs4x00_typeCimDataOut"
The "LHcs4x00_typeProcessDataOut" PLC data type contains the control bits for
the configured HCS4x00.
Table 4-10
Name
Data type
heat
Bool
mode
Bool
voltageComp
Bool
HCS4x00Library
Entry ID: 109478117,
V2.2.1,
Array with the entries for the configured HCS4x00 heating
control systems (size has to correspond to the number of
configured HCSs)
Data type
PLC data type with the control bits
PLC data type with the data of the PM to be written
Array with the channel value setpoints for the plugged
POMs
Switching the heating on/off (FALSE: off / TRUE: on)
Operating mode (FALSE: "Production" / TRUE: "Standby")
Mains voltage compensation: FALSE = off / TRUE = on (available when
using the PM4000 U/I, POM4220 Highend or POM4320)
09/2018
Description
Description
HW ID of the configured HCS4x00
Cyclic output data of the HCS4x00
Data record information
Description
Description
23