5.5 Storage
5.5.1 Drive Configurations
Table 5-8 Drive configurations
Configuration
4 x 3.5" drive
configuration
8 x 2.5" drive
configuration
10 x 2.5" drive
configuration 1
10 x 2.5" drive
configuration 2
10 x 2.5" drive
configuration 3
Issue 14 (2020-09-03)
Faulty DIMM isolation
Memory thermal throttling
Memory address parity protection
Memory demand/patrol scrubbing
Device tagging
Data scrambling
Adaptive double device data correction (ADDDC)
ADDDC+1
Copyright © Huawei Technologies Co., Ltd.
Maximum Front Drives
4
● Slots 0 to 3 support
only SAS/SATA drives.
8
● Slots 0 to 7 support
only SAS/SATA drives.
10
● Slots 0 and 1 support
only SAS/SATA drives.
● Slots 2 and 3 support
SAS/SATA/NVMe
drives.
● Slots 4 to 9 support
only NVMe drives.
10
● Slots 0 to 9 support
only SAS/SATA drives.
10
● Slots 0 to 5 support
only SAS/SATA drives.
● Slots 6 and 7 support
SAS/SATA/NVMe
drives.
● Slots 8 and 9 support
only NVMe drives.
5 Hardware Description
Drive Management
Mode
1 x RAID controller
a
card/PCH
1 x RAID controller
a
card/PCH
1 x RAID controller
a
card/PCH
1 x RAID controller card
1 x RAID controller
a
card/PCH