Gree GWH07AGA-K3NNA1B Service Manual page 102

Refrigerant r410a
Table of Contents

Advertisement

Service Manual
Step
14. Remove capillary sub-assy
Cut off the capillary welded tube to the
condenser and remove the capillary.
15. Remove 4-way valve assy
Cut off the welded pipe of the 4-way valve
component to the condenser assy and
compressor, and then remove the 4-way
valve.
Note:
When cutting weld, wrap the 4-way valve
with wet cloth completely to avoid damaging
the valve due to high temperature.
16. Remove compressor
Remove 3 foot nuts on compressor, and then
remove the compressor.
Note:
Protect the ports of discharge pipe and
suction pipe to avoid foreign objects to
enter it.
Installation and Maintenance
Procedure
welds
Capillary Sub-assy
welds
nuts
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents