ELECTRICAL SYSTEM CONTINUED
TROUBLESHOOTING THE GENERATOR
FAILS TO CRANK
CRANKS SLOWLY
CRANKS BUT WON'T
START
STOPS WHEN DRIVING
AROUND CORNER
UNIT STARTS AND
RUNS, THEN STOPS
WHEN SWITCH IS
RELEASED
CIRCUIT BREAKER
TRIPS
GENERATOR RUNS
THEN SURGES
2021 Wayfarer TM Series Owners Manual V1.0
1. Low Battery
2. Bad battery connection
Blown fuse
1. Low battery
2. Bad battery connection
3. Load connected
1. Fuel below 1/4 in tank
2. Low oil level
3. Plugged fuel filter, bad fuel
or fouled spark plug
1. Low on fuel
2. Low oil level
3. Excess oil
1. Low fluid levels
2. Possible overheating
3. Other function problem
Overloaded circuit
Started with load on
Start chassis engine then start
generator
Clean and tighten all battery
and cable connectons
Replace fuse on control panel
Start chassis engine then start
generator
Clean and tighten all battery
and cable connectons
Disconnect load before starting
Add fuel
Add oil if necessary
Contact an authorized service
technician
Add fuel
Add oil if necessary
Reduce generator oil level
Check and bring all fluid levels
up to approriate level
Checked for blocked air flow
and that the generator cover is
properly closed
Contact an authorized service
technician
Turn off some of the electrical
load and reset the circuit
breaker
Turn off all appliances and
restart generator