Chapter 2
2.7
The status LEDs allow you to check important functions and statuses on the deflection unit.
They are located on the front or on the top of the deflection unit (depends on type).
LED arrangement
10
RAYLASE 2-Axis Laser Beam Deflection Units
Status LEDs
Name Color
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
Meaning
Red
CLK fault
Red
Parity fault X
Red
Parity fault Y
Green
Temp. status X
Green
Temp. status Y
Orange
New data X
Orange
New data Y
Red
Fault X
Red
Fault Y
Green
+VCC
Green
-VCC
Basic information
Data transmission faulty.
Cable defective.
Temperature status available if
LEDs are lit.
Transfer new data if status
LEDs are lit.
Galvanometer scanner or
driver electronics defective.
Power supply defective if sta-
tus LEDs are flickering.
Power supplies available if
LEDs are lit.