"EE" FLASHING ON THE COOLBOT DISPLAY

Applies ONLY to the CoolBot Pro and CoolBot (Blue)
IMPORTANT! If you are NOT using Wi-Fi and you have an EE showing on the display follow these steps:
1.
Unplug the CoolBot from the power supply.
2.
Disconnect the Jumper from the CoolBot and disconnect the Data Cable (if they were connected).
3.
Plug your CoolBot back in. You will see EE.
4.
On the CoolBot, press the left arrow button until the Program light is solidly lit. You will see the firmware
version on the display (7.8, 7.9, etc.).
5.
Press the Checkmark button five times slowly, until you see "P1" on the display.
6.
Press the Left Arrow a few times to get to the reset option "CE".
7.
Once on the "CE" option press checkmark to select.
8.
Press the Left or Right Arrow until a "Y" shows on the display.
9.
Press Checkmark. Your CoolBot should stop blinking "EE" and revert back to show only the Room
Temperature (It is ready to use in the "No Wi-Fi Mode").
1.
On the CoolBot, press the left arrow button until the Program light is solidly lit. You will see the firmware
version on the display (7.8, 7.9, etc.).
2.
Press the Checkmark button five times slowly, until you see "P1" on the display.
3.
Press the Left Arrow a few times to get to the reset option you want to choose:
P1: resets all settings (Same as Fr)
Full factory reset of CoolBot and Jumper if the Jumper is connected.
Factory Reset of the CoolBot only, if the Jumper is disconnected.
ES: escapes from this menu and returns to normal operation
CJ: clears the Jumper's (Wi-Fi radio) settings only. The Jumper HAS to be connected to the CoolBot.
CE: Wi-Fi Mode disabled: Y=Not using Wi-Fi, N=Using Wi-Fi (See
CS: clears the CoolBot settings to defaults but keeps the Wi-Fi settings the same.
Fr: resets all settings (Same as P1)
4.
Press Checkmark to select that reset option.
5.
You will see a blinking "n" for "no". Press one of the arrow keys to change it to "y" for "yes."
6.
Press Checkmark. The CoolBot will reset the selected settings.
7.
If you chose P1, CJ, or Fr with the Jumper connected to the CoolBot, the CoolBot will switch to its Wi-Fi
Configuration mode. You should see the code "E0" on the display. This means the CoolBot pro and the
Jumper are ready to reconfigure the Wi-Fi connection.
8.
The CoolBot set temp has been reset to factory setting of 42°F, change it to your desired room temp.
Rev: 2020 – 3A

REBOOTING THE COOLBOT