NI 6589
1 Gbps, 20 Channel, LVDS Digital I/O Adapter Module
Note
Before you begin, complete the software and hardware installation
instructions in the getting started guide for your FlexRIO FPGA module or
Controller for FlexRIO.
The NI 6589 is a FlexRIO adapter module designed to work in conjunction with FlexRIO
FPGA modules and Controllers for FlexRIO.
The NI 6589 features 20 LVDS channels (16 data and 4 PFI), and sample rates up to 1 Gbit/s
on LVDS channels
This document explains how to install and configure the NI 6589.
Contents
Electromagnetic Compatibility Guidelines............................................................................... 1
FlexRIO Documentation........................................................................................................... 2
Verifying the System Requirements..........................................................................................4
Unpacking................................................................................................................................. 4
Preparing the Environment....................................................................................................... 4
Installing the NI 6589............................................................................................................... 5
Cables........................................................................................................................................5
Accessories........................................................................................................................6
Front Panel and Connector Pinouts...........................................................................................8
Block Diagrams.......................................................................................................................10
Component-Level Intellectual Property (CLIP)..................................................................... 12
NI 6589 CLIP..................................................................................................................13
Clocking.................................................................................................................................. 18
Where to Go Next................................................................................................................... 20
Worldwide Support and Services............................................................................................ 20

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits are designed to provide reasonable protection against harmful interference when the
product is operated in the intended operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments 6589

  • Page 1: Table Of Contents

    The NI 6589 is a FlexRIO adapter module designed to work in conjunction with FlexRIO FPGA modules and Controllers for FlexRIO. The NI 6589 features 20 LVDS channels (16 data and 4 PFI), and sample rates up to 1 Gbit/s on LVDS channels This document explains how to install and configure the NI 6589.
  • Page 2: Flexrio Documentation

    Caution To ensure the specified EMC performance, you must attach EMI gaskets (NI part number 746228-01) to both sides of your NI 6589 before using. Caution To ensure the specified EMC performance, you must install PXI EMC Filler Panels (NI part number 778700-01) in all open chassis slots.
  • Page 3 FlexRIO. IPNet Located at ni.com/ipnet. Contains LabVIEW FPGA functions and intellectual property to share. FlexRIO product page Located at ni.com/flexrio. Contains product information and data sheets for FlexRIO devices. NI 6589 Getting Started Guide | © National Instruments | 3...
  • Page 4: Verifying The System Requirements

    Store the devices in the antistatic package when they are not in use. Preparing the Environment Ensure that the environment you are using the NI 6589 in meets the following specifications. Operating temperature (IEC 60068-2-1, 0 °C to 55 °C...
  • Page 5: Installing The Ni 6589

    Use a shielded 50 Ω coaxial cable with an SMA plug end to connect to the PFI 0 and CLOCK IN connectors on the NI 6589 front panel. Use the NI SHB12X-B12X shielded cable (NI part number 192344-01) or the NI SHB12X-H3X24 differential flying-lead cable (NI part number 196236-1R5) to connect to the DDC connector.
  • Page 6: Accessories

    A flying lead cable, the NI SHB12X-H3X24, is also available for differential signals. This cable offers connectivity similar to that found on a typical logic analyzer, so you can use it in logic analyzer-type applications. This cable is shown in the following figure. 6 | ni.com | NI 6589 Getting Started Guide...
  • Page 7 For example, the signal shown on pin 1 maps to pin 73 at the end connector. For more information about connecting I/O signals on your device, refer to the NI 6589 Specifications. NI 6589 Getting Started Guide | © National Instruments | 7...
  • Page 8: Front Panel And Connector Pinouts

    Front Panel and Connector Pinouts The NI 6589 provides one PFI signal and one clock signal through the two SMA connectors on the device front panel. Additionally, the NI 6589 provides sixteen LVDS signals, four LVDS PFI signals, three single-ended PFI signals, and an LVDS clock out signal on the Digital Data &...
  • Page 9 73 in the pinout at the end connector. The following table contains SMA pin location information and signal information for the NI 6589. The signal names listed in this table refer to the signals shown in the front panel pinout.
  • Page 10: Block Diagrams

    19, 22, 25, 28, 31, 34, 37, 40, 42, 46, 49, 52, 55, 58, 69 For more detailed information about the NI 6589 front panel connectors, refer to the NI 6589 Specifications. Block Diagrams The following figures show the data flow through the NI 6589. Single-ended data lines use standard clock levels to interpret data as either a binary zero or a one in high-speed digital data transfers.
  • Page 11 NI FlexRIO FPGA Module (GPIO Direction) LVDS DDC CLK OUT+ Clock from NI FlexRIO FPGA Module 110 Ω LVDS (GPIO Output) DDC CLK OUT Switch 10 kΩ 10 kΩ NI 6589 Getting Started Guide | © National Instruments | 11...
  • Page 12: Component-Level Intellectual Property (Clip)

    The FlexRIO adapter module ships with socketed CLIP items that add module I/O to the LabVIEW project. Related Information Block Diagrams on page 10 12 | ni.com | NI 6589 Getting Started Guide...
  • Page 13: Ni 6589 Clip

    NI 6589 CLIP Refer to the following table for the available NI 6589 CLIP items, and each CLIP item's function and available signals. Note All NI 6589 CLIP items allow individual clock output inversion. NI 6589 Getting Started Guide | © National Instruments | 13...
  • Page 14 • Four single-ended PFI factor of 10 by default. During acquisition, the lines NI 6589 reads or writes ten bits of data per • One single-ended clock channel to or from the ISERDES or input signal OSERDES blocks.
  • Page 15 All OSERDES and ISERDES blocks are set to double data rate (DDR) mode. The following table lists the NI 6589 SMA connector signals and corresponding FlexRIO FPGA module signals necessary for designing custom component-level IP (CLIP). Table 5. NI 6589 SMA Signals and FlexRIO FPGA Module Signals...
  • Page 16 Table 6. NI 6589 DDC Signals and FlexRIO FPGA Module Signals NI 6589 FlexRIO FPGA Module Signal Name GPIO Input GPIO Output GPIO Direction PFI 1+ GPIO_39_CC GPIO_36 GPIO_14 PFI 1- GPIO_39_n_CC GPIO_36_n PFI 2+ GPIO_40_CC GPIO_41 GPIO_14_n PFI 2-...
  • Page 17 Table 6. NI 6589 DDC Signals and FlexRIO FPGA Module Signals (Continued) NI 6589 FlexRIO FPGA Module Signal Name GPIO Input GPIO Output GPIO Direction DIO 8+ GPIO_53 GPIO_30 GPIO_8 DIO 8- GPIO_53_n GPIO_30_n DIO 9+ GPIO_52 GPIO_25 GPIO_9 DIO 9-...
  • Page 18: Clocking

    NI 6589 with a socketed CLIP, and a list of available socketed CLIP signals. Clocking The clocks on the NI 6589 control the sample rate and other timing functions on your FlexRIO system. The following figure shows the NI 6589 clock sources routed through the crosspoint switch.
  • Page 19 Strobe Bypass—LVDS STROBE bypasses the crosspoint switch. The propagation delay of the Strobe Bypass exactly matches the propagation delay of the data channels. This setting is ideal for source- synchronous applications. NI 6589 Getting Started Guide | © National Instruments | 19...
  • Page 20: Where To Go Next

    A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You 20 | ni.com | NI 6589 Getting Started Guide...
  • Page 21 United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI 6589 Getting Started Guide | © National Instruments | 21...
  • Page 22 CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2016 National Instruments. All rights reserved. 374729B-01 Apr16...