Bullard PA30IS Series User Manual

Bullard PA30IS Series User Manual

Powered air-purifying respirator

Advertisement

Quick Links

Approval No. TC-21C-0825
PA3IS - Powered Air-Purifying Respirator with High Efficiency (HE) Filters (2)
Approval No. TC-23C-2306
PA3IS - Powered Air-Purifying Respirator with PA3NBC cartridges (3) for
chlorine, hydrogen chlorine, sulfur dioxide, chlorine dioxide, hydrogen fluoride,
ammonia, methylamine, and particulates
Approval No. TC-23C-2384
PA3IS - Powered Air-Purifying Respirator with OV-AG-HE Cartridges (3) for
organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide or
hydrogen fluoride and particulates
PA30IS PAPR
Cautions and Limitations
A. Not for use in atmospheres containing less than 19.5% oxygen.
B. Not for use in atmospheres immediately dangerous to life or health.
C. Do not exceed maximum use concentrations established by regulatory
standards.
F. Do not use respirator if airflow is less than four cfm (115 lpm) for tight fitting
face pieces or six cfm(170 lpm) for hoods and/or helmets.
H. Follow established cartridge and canister change schedules or observe ESLI
to ensure that cartridges and canisters are replaced before breakthrough.
I. Contains electrical parts that may cause an ignition in flammable or explosive
atmospheres.
J. Failure to properly use and maintain this product could result in injury or
death.
L. Follow the manufacturer's user instructions for changing cartridges and/or
filters.
M. All approved respirators shall be selected, fitted, used and maintained in
accordance with MSHA, OSHA and other applicable regulations.
N. Never substitute, modify, add or omit parts. Use only exact Bullard
replacement parts in the configuration as specified by the manufacturer.
O. Refer to User's Instructions and/or maintenance manuals for information on
use and maintenance of these respirators.
P . NIOSH does not evaluate respirators for use as surgical masks.
As of November 1, 2013, the PA30IS PAPR Blower is no longer certified for use in
Hazardous Classified Locations.

Table of Contents

Warnings, Cautions and Limitations .................................................................... 1
Principle of Operation ......................................................................................... 2
Battery Pack ......................................................................................................... 2
Pre-Operational Inspection .................................................................................. 3
Mounting the Breathing Tube ................................................................................ 3
Checking Air Flow ................................................................................................. 3
Air-Purifying Elements ......................................................................................... 4
PA30IS Series Powered Air-Purifying Respirator
NOTICE
www.bullard.com
PA3IS Blower Assembly User Manual
(for use with Loose-Fitting Headtops)
WARNING
Use strictly in accordance with instructions, labels and limitations pertaining to
the PA30IS respirator.
1. The PA30IS respirator does not supply oxygen. Use only in adequately
ventilated areas containing at least 19.5% oxygen.
2. Do not use when concentrations of contaminants are immediately
dangerous to life or health (IDLH). This term is defined in
29CFR 1910.134 (b).
3. Do not use these respirators for respiratory protection during abrasive
blasting or clean up.
4. Do not use in circumstances where the airborne concentration level of
contaminant exceeds maximum use concentration for this type of respirator
as established by regulatory standards.
5. Leave area immediately if:
• Breathing becomes difficult
• Dizziness or other distress occurs
• You taste or smell the contaminant
• Unit becomes damaged
• Voltage alarm activates
6. This apparatus must not be worn with the blower unit switched off. If the
blower is switched off, a rapid build-up of carbon dioxide and depletion of
oxygen may occur, which could result in death or serious injury.
7. Never alter or modify this respirator. Use only Bullard PA30IS Series
components and replacement parts approved for use with this respirator.
Failure to follow these warnings could result in death or serious injury.䍃
Mounting and Replacing Cartridges ..................................................................... 5
Donning the Blower .......................................................................................... 5-8
Low Battery Alarm ............................................................................................... 8
Troubleshooting .................................................................................................... 8
Cleaning and Storage ............................................................................................ 9
Niosh Approval Label .......................................................................................... 10
Ordering Information .......................................................................................... 11

Advertisement

Table of Contents
loading

Summary of Contents for Bullard PA30IS Series

  • Page 1: Table Of Contents

    7. Never alter or modify this respirator. Use only Bullard PA30IS Series NOTICE components and replacement parts approved for use with this respirator.
  • Page 2: Principle Of Operation

    Figure 1 20SICH/20SICHT Hood with taped and sealed seams for use with Bullard hard hat the PAPR for more than 20 minutes after the alarm has been activated may damage the 2 0SICVH/20SICVHT Hood with taped and sealed seams and PVC lens for use with battery.
  • Page 3: Pre-Operational Inspection

    • Inspect the hood or loose fitting facepiece for any physical damage. DO NOT use a blower that fails the flow test. Use ONLY Bullard cartridges which comply with and have the NIOSH approval label and which are appropriate for the contaminant. Failure to observe these warnings could result in death or serious injury.
  • Page 4: Air-Purifying Elements

    If liquid exposure is encountered, the respirator should not be used for more than two (2) hours. Follow established cartridge change schedules to ensure that cartridges are replaced before breakthrough occurs. Failure to follow these warnings could result in death or serious injury. www.bullard.com...
  • Page 5: Mounting And Replacing Cartridges

    Contact WARNING Bullard for further information on change-out schedules. The use of any cartridge not approved with the PA3ISBU blower units may put High efficiency particulate filters must be replaced when retained particles clog the user at risk and could result in death or serious injury.
  • Page 6 (20SICH & 20TICH) and repeat steps 2-4. 1. Assemble and adjust the standard Bullard hard hat suspensions RS4PC or For hoods with a threaded port at the rear (designated with a “T” suffix), RS6PC or the optional ratchet suspensions RS4RC or RS6RC by following Breathing Tubes PAHBT, PAHBTXS, PAHBTXL will attach to the hood by the the directions on instruction sheet attached to headband on hard hat.
  • Page 7 PA30IS Series Powered Air-Purifying Respirator PA3IS Blower Assembly User Manual RT Series Hood Use WARNING Installing Breathing Tube Assembly in RT Series The user should ensure that the neck cuff is unrestricted all around the neck Respirator Hoods to allow proper inflation and reduce restrictions.
  • Page 8: Low Battery Alarm

    Blower unit does not run for full service life Improper initial charge Review “Initial Charging Procedure” page 3 PA3IS (Approximately 7 hours with 1 Prolonged storage of unit not on charger Review guidelines for maximizing battery life, page 2 battery pack) (under Battery Pack). Deeply discharged battery www.bullard.com...
  • Page 9: Cleaning And Storage

    PA30IS Series Powered Air-Purifying Respirator PA3IS Blower Assembly User Manual Cleaning WARNING Once cartridges have reached the end of their useful life, discard in accordance Avoid contaminant entry into the breathing tube, as this will compromise with federal, state, and local guidelines, and in conformance with plant safety respiratory protection and could result in death or serious injury.
  • Page 10: Niosh Approval Label

    BeLts BatteRY aLteRnate CHaRGeR assemBLies aLteRnate CaRtRiDGes FiLteR poRt pLUG BLoWeR Unit aLteRnate BReatHinG tUBes aLteRnate sUspension / HaRD Hat assemBLies www.bullard.com...
  • Page 11: Ordering Information

    Tychem QC, with 20TG headband suspension PA1SB Standard belt 20TICN/20TICNT Tychem QC, no headband suspension PA1DB Decon belt Hood with inner bib, for use with Bullard hard hat PA1EB Extension standard belt kit 20TICH/20TICHT Tychem QC, hard hat not included PA1DEB Extension decon belt kit...
  • Page 12 9001 certified Americas: Europe: Asia-Pacific: Bullard Bullard GmbH Bullard Asia Pacific Pte. Ltd. 1898 safety Way Lilienthalstrasse 12 LHK Building Cynthiana, KY 41031-9303 53424 Remagen • Germany 701, sims Drive, #04-03 ©2013 Bullard. All rights reserved. toll free: 877-BULLaRD (285-5273)

This manual is also suitable for:

Pa3is