Ac Wiring Procedure - Xantrex PROwatt 1000 Owner's Manual

Xantrex technology inverter owner's guide prowatt 1000
Hide thumbs Also See for PROwatt 1000:
Table of Contents

Advertisement

AC Wiring Procedure

To make a permanent connection to existing AC wiring:
1. Make sure no DC voltage is being supplied to the inverter, and make
2. Remove the bottom plate from the inverter. This gives you access to the
3. Remove the knockout on the DC end of the inverter.
4. Feed 3-conductor 14 AWG AC cable through the hole.
5. Insert a cable clamp for electrical junction boxes to hold the cable in
6. Connect the ground lead of the AC cable (green or bare wire) to the
7. Strip 1/4 inch (6 mm) of insulation from the line (black) and neutral
8. Replace the inverter's bottom panel.
sure no AC voltage is present on the AC wiring.
AC terminal blocks. See
place.
internal terminal block labelled
ground lead to a grounding point on a junction box or breaker panel.
Make sure the ground lead is cut as short as possible and is not touching
any component within the inverter.
(white) leads, and connect them to the AC output terminal blocks on the
PROwatt 1000 circuit board. These terminal blocks are labeled
and
respectively as shown in
AC NEUT
CAUTION: Reverse Polarity
Improper connections (connecting a line conductor to a
neutral conductor, for example) will cause the PROwatt 1000
to malfunction and may permanently damage the inverter.
Damage caused by a reverse polarity connection is not
covered by your warranty.
Ensure that you have maintained correct polarity and that there are no
loose strands of wire.
Connecting to an Existing AC Circuit
Figure
3-1.
. Connect the other end of the
AC GND
Figure
AC HOT
3-1.
3–7