Figure 9, Ac Input/Output Power Connection; Table 1, Ac Input And Output Wiring Connections - Xantrex 120 VAC/60 Owner's Manual

Sw series inverter/chargers
Table of Contents

Advertisement

Note: The three neutral terminals are common to each other and can be used in any combination or
order. In a residential application, it is often easier to only connect one AC neutral wire to the inverter and
make the other neutral connections at a central point such as in the AC load center, etc. In mobile
installations, the AC system must have the neutral physically isolated from the ground throughout the load
distribution powered by the inverter. The SW Series Inverter/Charger does not include neutral to ground
switching for the AC electrical system. This must be done externally from the inverter. See the NEUTRAL-
TO-GROUND BOND SWITCHING (RV AND MARINE APPLICATIONS) section on page 27 for more
information.
AC Terminal Block
(TB1)
AC IN 2
From
Generator Power

Figure 9, AC Input/Output Power Connection

Before making any AC connections, make sure that the inverter is disconnected from the battery (or
battery bank). Feed the wires through conduit fittings located on the left side or left bottom side of the
inverter. (Note: Conduit fittings must be purchased separately and are required by code to comply with
residential and commercial installations).
The AC wiring both in and out of the inverter must also be protected from short circuits and overloads by a fuse
or circuit breaker. Consult the NEC or your local code for more information and for other wire sizes. Table 13 on
page 132 gives suggestions for wire sizing. Follow the wiring guide on the circuit board inside the cover plate
(see Figure 9, above). Connect the AC wiring as follows (from front to back when wall mounted):
AC CONNECTIONS
AC HOT IN 1
NEUTRAL IN 1
AC HOT IN 2
NEUTRAL IN 2
AC HOT OUT
NEUTRAL OUT
2001 Xantrex Technology, Inc.
5916 - 195th Street N. E.
Arlington, WA 98223
1a
2a
3a
4a
5a
6a

Table 1, AC Input and Output Wiring Connections

AC TERMINAL BLOCK #
1b
3b
2b
4b
6b
5b
Telephone: 360/435-8826
Fax: 360/435-2229
www.traceengineering.com
INSTALLATION
1b
2b
3b
4b
5b
6b
WIRE COLOR
Black (Hot)
White (Neutral)
Black (Hot)
White (Neutral)
Black or Red (Hot)
White (Neutral)
SW Series Inverter/Charger
Part No. 2031-5
Rev. C: February 2001
AC IN 1
From
Utility Power
AC OUT
To
AC Loads
PURPOSE
Utility Power
Utility Power
Generator
Generator
AC Loads
AC Loads
Page
19

Advertisement

Table of Contents
loading

Table of Contents