Insufficient Flow; Pump Runs At Maximum Speed And Cannot Be Controlled; Fault Indication On The Operating Panel - Grundfos UPM3S Series Data Booklet

Table of Contents

Advertisement

14
Remedy
Remove impurities. Deblock the pump from the front of the control box with a screwdriver.
Cause
Pump is defective.
Remedy
Replace the pump.

Insufficient flow

Cause
Pump performance is too low.
Remedy
Check the external controller and the pump settings.
Cause
Hydraulic system is closed or system pressure is insufficient.
Remedy
Check the non-return valve and filter. Increase the system pressure.

Pump runs at maximum speed and cannot be controlled

Cause
No signal from signal cable.
Remedy
Check if the cable is connected to the controller. If it is, replace the cable.

Fault indication on the operating panel

When an alarm is active, the LEDs indicate the alarm type as defined in the table below.
If multiple alarms are active at the same time, the LEDs only show the error with the highest priority. The priority is defined
by the sequence of the table.
LED1
LED2
red
green
See also https://www.youtube.com/watch?v=cMC02526Z_s.
58
Operating panel
LED3
LED4
yellow
yellow
LED5
Indication
yellow
Rotor is blocked.
Supply voltage too low.
Electrical error.
Pump operation
Counter action
Trying to start again
Wait or deblock the
every 1.33 seconds.
shaft.
Only warning, pump
Control the supply
runs.
voltage.
Pump is stopped
Control the supply
because of low supply
voltage.
voltage or serious
Replace the pump.
failure.
UPM3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Upm3 seriesUpm3l seriesUpmo series

Table of Contents