A measured step forward EASYDOS Peristaltic V Operating & Operating & Operating & Operating & Operating & Maintenance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Read these operation & maintenance instructions before start up! To be held for future reference.
Warnings used in this Operation & Maintenance Manual ............... 4 Parts designation ............................5 Peristaltic pump EASYDOS Peristaltic V ....................6 Basic equipment / properties ........................6 Technical Data ............................. 7 Installation and safety regulations ......................7 Installing the unit ............................
Warnings used in this Operation & Maintenance Manual This Operation & Maintenance Manual contains vital information, which may endanger people, the environment and the dosing pump/system if disregarded. These statements are identified by the following symbols: DANGER! Refers to an imminent danger. Non-compliance can lead to death or extremely serious injury.
Peristaltic pump EASYDOS Peristaltic V Universal peristaltic pump with closed-loop revolution controlled drive for continuous and time relay controlled dosage of process fluids (4 modes of operation). Basic equipment / properties • self-priming peristaltic pump with genuine closed-loop speed control (GCL- technology) •...
Technical Data Capacity: 7 – 400 ml/h (water at 20° C (68° F), suction height 1.7 m) Pump tube: 0.8 x 1.6 mm Recommended operation time: up to 8 h/d Duty cycle: 100 %/h, if adjusted to <1/3 of max speed 50 %/h, if adjusted to >1/3 of max speed of the recommended operation time System back pressure:...
Installing the unit • On the inner sides of the big coloured front hood in the area of the tube retainer there are two slots of about 9 mm length. Loosen front hood carefully at these two slots with a screw driver and remove front hood by hand (see last page). •...
Setting the mode of operation The desired mode of operation is selected with a jumper (small electrical bridge) on the electronic circuit board by simply putting it on the corresponding pin couple. Default setting of the device is mode of operation 1 (shown in the figure on the right side).
• Set jumper on printed circuit board to position 1 (if not default). • Attach neutral conductor to terminal 1, power supply (230 V AC) to terminal 2 and attach control current (230 V AC) to terminal 3. • If no controlling voltage is available, terminals 2 and 3 must be jumped. NOTICE! Power supply on terminal 2 and control current terminal 3 must be in phase! •...
Page 10
• With potentiometer P2 a time period between 1 and 20 seconds can be set. • With the control voltage „In2“ (230 V AC) at terminal 4, the perestaltic pump operates for the set time at constant rotor speed (capacity approx. 6 ml/min. •...
Mode of operation 3: 1 time relay with adjustable rate of delivery on channel 1 • Set jumper on printed circuit board to position 3 (default is position 1) • Put neutral conductor to terminal 1 and phase / mains (230 V AC) to terminal 2 •...
• With active control voltage on terminal 4 („In 2“) terminals 5 (neutral) and 6 (phase) are active (230V AC). An optional LED is in series with a resistor (470 Ohms) between terminals 9 and 10. This special mode is intended to gather the error state of any device of a multiple device dosage station to the last device, which forwards the error state to a computer system or an additional external warning signal.
factory. If necessary, the rate of delivery can be adjusted by potentiometers P1 and P2 in the range, that is specified in the chapter ”Technical Data“. If a different mode of operation is required, refer to section „setting mode of operation“. Safety in case of a ruptured pump tube When using electrical conductive process fluid, a damage of the pump tube is detected by electrodes.
Read the material safety data sheet (MSDS) of the process fluid and obey the described safety measures! WARNING! IMPORTANT! Use original Lutz-Jesco pump tube only! The use of different tubes may damage the drive. Never grease the tube! IMPORTANT! CAUTION! Before changing the tube always ensure, that the tubes don’t contain residue of the...
If the product is modified without our consent, this declaration loses its validity. Product description: Perestaltic Pump Model designation: EASYDOS Peristaltic V Relevant EC regulations: EC Low-Voltage Directive (73/23/EEC) EC Electromagnetic Compatibility Directive (93/68/EEC)
(i.e. chemical, biological, toxic, flammable, and radioactive material) and that the lubricant has been drained.*) If Lutz-Jesco has to (further) clean the unit the costs will be charged to us. We assure that the aforementioned information is correct and complete and that the unit is dispatched according to the legal requirements.
Warranty Please copy this page and send it back with the EASYDOS Peristaltic V! If the dosing pump fails during the warranty period, please return the cleaned EASYDOS Peristaltic V with the completed warranty claim. Sender Company: ..............Phone: ........Date: ........