Page 1
MIDIDOS E Operation & Maintenance Instructions Read these operation and maintenance instructions before start up! To be held for future reference. Dosing Liquids Conveying Gases Control Systems...
11.1 Lubricants ......................................19 11. Maintenance of storage ..................................19 11. Replacing the diaphragm ...................................0 11.4 Valves ........................................ 1. Spare parts list MIDIDOS E 4...7 ...............................6 1. Spare parts list MIDIDOS E 10 ................................8 1. Troubleshooting ....................................0 14. Declaration of conformity .................................. 15.
1. Safety 1.1 General This Operation & Maintenance Manual contains basic information to be noted during installation, operation and maintenance. It is therefore essential that the contractor read the manual before installing and commissioning the pump/system as well as by the relevant operating personnel/owner of the pump/system.
1.3 Qualification and training of personnel The personnel employed for installation, operation, inspection and maintenance work must be qualified to do so. The areas of responsibility, competence and supervision of the personnel must be precisely defined by the owner. Personnel who do not have the required knowledge must be duly rained and instructed.
The following hazard in particular may arise: • Danger to people due to electrical, mechanical and chemical effects. • Failure of dosing pump/system functions. • Failure of specified methods for maintenance and repair. • Danger to the environment due to leakage of hazardous substances. 1.6 Safe operation The safety instructions in this Operation &...
1.11 Dosing of chemicals CAUTION! • When working on dosing systems, the accident prevention regulations applicable on-site must be observed and the specified personal protective clothing is recom- mended, depending on the hazard associated with the metered medium: CAUTION! Googles Protective gloves Protective suit •...
If there is a danger of fluid collecting underneath the base of the pump, the pump must be elevated. CAUTION! DANGER! • Fire hazard. Pressure surge: catapulting parts could kill you. MIDIDOS E must not be used under any circumstances in an explosive environment. DANGER! 1.12 Scope of delivery...
2. General Dosing pumps are used to add chemicals in various processes. As leak free diaphragm dosing pumps with a dosing range of between max. l/h and 10 l/h the MIDIDOS E has a broad field of application. The MIDIDOS E is supplied as a simple dosing pump with the dosing head mounted on the left hand side.
4. Technical data MIDIDOS E 24 E 48 E 72 E 120 Flow rate [l/h] - max. pressure [bar] 4 - 10 48 - 10 7 - 6 114 - 4 max. pressure at 1~ mode [bar] Hub frequency [1/min] Hub volume [ml/Hub] 0.8 Diaphragm-Ø...
Page 11
Hubeinstellung Hubeinstellung MIDIDOS E48 Hubeinstellung MIDIDOS E48 MIDIDOS E48 2 bar 2 bar 10 bar 2 bar 10 bar 10 bar Hubeinstellung Hubeinstellung Stroke adjustment Hubeinstellung MIDIDOS E72 MIDIDOS E72 MIDIDOS E72 2 bar 2 bar 6 bar 2 bar 6 bar 6 bar Hubeinstellung...
7. Installation 7.1 General information For the selection of a dosing pump when designing a system as well as for the installa- tion and operation, local rules and regulations must be obeyed. This applies to the se- lection of appropriate materials of construction for the pump, the handling of chemicals and the electrical installation.
position. To guarantee its stability, the pump must be screwed appropriately into the ground. The system’s piping must not put any force on the dosing pump’s connections or val- ves. To avoid backfiring dosing after the process end, an electrical and hydraulically locking device is provided on the dosing pump.
Safety and pressure relief valves protect the dosing pump and the associated accessori- es and lines from overloads. They prevent an impermissibly high increase of pressure on the discharge side of the dosing pump that may be caused for example by the accidental closing of valves whilst the pump is in operation or by a clogged injector.
Page 16
Electrical connection data (variants on request) Pump sizes voltage output electricity MIDIDOS [Watt] E 4...10 400/0 0,50/0,87 50 Hz 440/54 0,46/0,80 60 Hz 400/0 0,4/0,7 60 Hz 0/1-Phase 0,85 50 Hz Connection system for the driving motor • supply of three-phase current Y-Schaltung -Schaltung Y-circuit...
7.7 Installation example Legend 1. MIDIDOS E . Electric agitator . Chemical tank 4. Pulsation dampener 5. Pressure relief valve (safety valve) 6. Diaphragm stop-valve 7. Injection nozzle 8. Stroke length setting CAUTION! The pump’s stroke length is to be moved only when the motor is running!
9. Start up NOTICE! Personal protective equipment as specified by on-site regulations must be worn at all times while working on the dosing pump! CAUTION! Goggles Protective gloves Protective suit 1. Before starting up the dosing pump all the stages for “Installation” in chapter 7 have to be carried out.
10. Shutdown Before starting any maintenance and before prolonged downtime, drain the chemical from the pump and rinse it out with a neutral medium. CAUTION! Excess chemicals must be disposed of in accordance with local rules and regulations. Note the applicable accident prevention regulations and wear personal protective clo- thing.
CAUTION! Legend 1. Dosing head . Diaphragm . Supporting plate (with the MIDIDOS E 4, 48 and 7) 4. Diaphragm chamber 6. Diaphragm insert 7. Motor Changing the diaphragm Picture 1 1.
Page 21
A tightening torque of Nm is required for the do- sing head screws on the MIDIDOS E4... E7 and 6 Nm for the MIDIDOS E10. Picture 5 Picture 5...
11.4 Valves The dosing pump valves have to be cleaned on a regular basis. CAUTION! Chemicals may spray out causing caustic as well as other burns. Before working on the pump, release any pressure and wash with water or another suitable medium. CAUTION! NOTICE! Unclean valves will reduce the dosing accuracy.
Page 26
12. Spare parts list MIDIDOS E 24...72 MIDIDOS E 4...7 h Diaphragm 81465 i Support plate 8977 g Dosing head including screws Material Order no.: 909 4661 PVDF 0 Stainless steel 1.4571 911...
Page 27
Spare parts for MIDIDOS E 24...72 with double balls/valves Consisting of: Material Order no.: a balls PVC/Glas/FPM 875 c valve seats PVC/Glas/CSM 874 d O-ring h diaphragm PP/Glas/FPM 5567 PP/Glas/CSM 546 PVDF/PTFE/FPM 5756 Stainless steel / FPM 877 e Double ball valve DN6 komplett Material Order no.:...
12. Spare parts list MIDIDOS E 120 MIDIDOS E 10 h Diaphragm 81466 g Dosing head inclusive of screws Material Order-no.: 806 PP grey 8178 Stainless steel 1.4571 890 PVDF 89...
Page 29
Spare parts for MIDIDOS E 120 with double ball valves Consisting of: Material Order-no.: a balls PVC/Glas/FPM 8196 c valve seats PVC/Glas/CSM 8197 d O-rings h Diaphragm PP/Glas/FPM 801 PP/Glas/CSM 800 Stainless steel / FPM 80 PVDF/PTFE/FPM 810 e Double ball valve DN10 complete Material Order-no.:...
- Install priming aid Viscosity too high. - Install spring-loaded valves - Enlarge the pipe cross section - Use a special dosing head. >> Contact Lutz-Jesco No existing stroke motion. Dosing pump set on 0 strokes. Correctly adjust the pump stroke length.
Page 31
Dosing pump powers strength Defective anti-friction bearings. Replace the gear-box. noises. Gear-box without molybdenum- e.g. renew with Molycote. disulfide. Motor throbs but doesn’t draw Wrong connection Check electrical connection condensator defective, wrong Eventual condensator correctly size or wrongly connected. clamped on or replaced. Pressure too high.
If the product is modified without our consent, this declaration is no longer valid. Product description: Diaphragm-dosing pump Model designation: Minidos A, Mididos E, Memdos TM, Memdos M, Memdos ML, Memdos E, Memdos MR, Memdos GMR Relevant EC regulations: EC- Low voltage Directive (7//EEC)
*) If Lutz-Jesco find it necessary to carry out further cleaning work, we accept the charge will be made to us. We certify that the aforementioned information is correct and complete and that the unit is dispatched in compliance with legal requirements.
16. Warranty Please copy and send with MIDIDOS E! If the dosing pump breaks down within the period of warranty, please return the MIDIDOS E in a cleaned condition with the complete warranty application, filled out. Sender Company: ................ Phone:........Date: ........