Control 4 C4-KC240 Installation Manual
Control 4 C4-KC240 Installation Manual

Control 4 C4-KC240 Installation Manual

Configurable keypad

Advertisement

Quick Links

Supported Model
C4-KC240 Wireless Configurable Keypad, 240V
Introduction
The Control4® Configurable Keypad is intended for use in a Control4 system. It
installs in a standard wallbox using typical wiring standards and communicates to
the Control4 system using a wireless connection.
Box Contents
Configurable Keypad
Keycap Button Kit
Terminal Block
Warranty Card
Configurable Keypad Installation Guide (this document)
Keypad Buttons Installation Guide
Specifications
The specifications are described below.
Model Number
Power Requirements
Power Consumption
Operational Temperature
Humidity
Storage
Control Communications
Wallbox Volume
Weight
Shipping Weight
Configurable
Keypad
Installation Guide
C4-KC240-xx
220VAC-240VAC +/-10% 50/60 Hz
36-48VDC
This device requires a neutral AC
connection.
240V: 480mW
36VDC: 430mW
Environmental
32˚ F - 104˚ F (0˚ C - 40˚ C)
5% to 95% non-condensing
-4˚ F - 158˚ F (-20˚ C - 70˚ C)
Miscellaneous
ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
4.75 cubic inches (77.8 cubic centimeters)
0.12 lb. (0.05 kg)
0.18 lb. (0.08 kg)
Warnings and Considerations
WARNING!
Turn OFF electrical power before installing or servicing this
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
WARNING!
This device must be protected by a circuit breaker (20A max).
WARNING!
Ground this device in accordance with the National Electric
Code (NEC) requirements. DO NOT rely solely upon the yoke plate's
contact with a metal wallbox for adequate grounding. Use the device's
ground wire to make a secure connection to the safety ground of the
electrical system.
IMPORTANT!
This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
If you are unsure about any part of these instructions,
IMPORTANT!
consult a qualified electrician.
IMPORTANT!
Use this device only with copper or copper-clad wire. Do
not use aluminum wiring. This product has not been approved for use with
aluminum wiring.
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See "Troubleshooting."
IMPORTANT!
Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT!
This is an electronic device with intricate components.
Handle and install with care!
Installation Instructions
1
Ensure that the location and intended use meet the following criteria:
When replacing a traditional 3-way switch, refer to the "Two-Location"
sample wiring configurations provided in the appropriate load control device
installation guide.
Install in accordance with all national and local electrical codes.
The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout of the
home; (3) walls separating devices; and (4) electrical equipment located near
devices.
2
Turn off the mains electrical power at the consumer unit. To ensure the wires
do NOT have power running to them, use an inductive voltage detector.
NOTE:
The wallbox wiring shown in this document is an example. Your
wire colors and functions may differ. If you are not sure which wires are
the Hot, Neutral, and Ground wires, have a trained electrician do the
installation.
3
Prepare each wire. Wire insulation should be stripped back 7mm from the
wire end (see Figure 1).

Advertisement

loading

Summary of Contents for Control 4 C4-KC240

  • Page 1 • C4-KC240 Wireless Configurable Keypad, 240V IMPORTANT! This device must be installed by a licensed electrician in accordance with all national and local electrical codes.
  • Page 2 Turn ON mains electrical power at the consumer unit. Figure 1. Strip Wire Insulation Operation and Configuration On initial power up, all status LEDs on the keypad will illuminate green indicating that the device has power. Until the keypad has been configured into a Control4 system, it will not control any loads.