STEP
(After having opened and
+
closed again the door)
8
Press once the +
+
9
Press once the
+
10
Press once the
Service Manual
Evolution - 2005
RUN AND DISPLAY
+
+
Tangential fan and heating cover are supplied. Open
the door to check the temperature of the cavity top.
The top must become very hot
NO: Check the wiring and the heating cover.
The ohm-value must be around: 372
CONTINUE THE TEST
'Ver on' is displayed and the thermal activator is
supplied. : The valve is closing slowly
NO: Check the supply of the activator and its resistance
(1k )
CONTINUE THE TEST
Edition
2005.03.39
REMARKS
End of the test