Download Print this page
EVAPCO LPT Series Rigging And Installation Manual

EVAPCO LPT Series Rigging And Installation Manual

Forced draft cooling towers; forced draft closed circuit coolers; forced draft evaporative condensers

Advertisement

Quick Links

LPT SERIES FORCED DRAFT COOLING TOWERS
LRW SERIES FORCED DRAFT CLOSED CIRCUIT COOLERS
LRC SERIES FORCED DRAFT EVAPORATIVE CONDENSERS
Contact Your Local Mr. GoodTower
EVAPCO, Inc. — World Headquarters & Research/Development Center
P
EVAPCO North America
EVAPCO, Inc.
World Headquarters
P.O. Box 1300
Westminster, MD 21158 USA
Phone: 410-756-2600
Fax: 410-756-6450
E-mail: marketing@evapco.com
EVAPCO East
5151 Allendale Lane
Taneytown, MD 21787 USA
Phone: 410-756-2600
Fax: 410-756-6450
E-mail: marketing@evapco.com
EVAPCO Midwest
1723 York Road
Greenup, IL 62428 USA
Phone: 217-923-3431
Fax: 217-923-3300
E-mail: evapcomw@evapcomw.com
EVAPCO West
1900 West Almond Avenue
Madera, CA 93637 USA
Phone: 559-673-2207
Fax: 559-673-2378
E-mail: contact@evapcowest.com
EVAPCO Iowa
925 Quality Drive
Lake View, IA 51450 USA
Phone: 712-657-3223
Fax: 712-657-3226
EVAPCO Iowa
Sales & Engineering
215 1st Street, NE
P.O. Box 88
Medford, MN 55049 USA
Phone: 507-446-8005
Fax: 507-446-8239
E-mail: evapcomn@evapcomn.com
EVAPCO...
S
PECiAliStS in
P
rOduCtS And
Rigging and
Installation Manual
For EVAPCO Authorized Parts and Service,
or the EVAPCO Plant Nearest You
EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA
: 410-756-2600 • F
hone
ax
Refrigeration Valves &
Systems Corporation
A wholly owned subsidiary of EVAPCO, Inc.
1520 Crosswind Dr.
Bryan, TX 77808 USA
Phone: 979-778-0095
Fax: 979-778-0030
E-mail: rvs@rvscorp.com
McCormack Coil Company, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
P.O. Box 1727
6333 S.W. Lakeview Boulevard
Lake Oswego, OR 97035 USA
Phone: 503-639-2137
Fax: 503-639-1800
E-mail: mail@mmccoil.com
EvapTech, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
8331 Nieman Road
Lenexa, KS 66214 USA
Phone: 913-322-5165
Fax: 913-322-5166
E-mail: marketing@evaptech.com
Tower Components, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
5960 US HWY 64E
Ramseur, NC 27316
Phone: 336-824-2102
Fax: 336-824-2190
E-mail: mail@towercomponentsinc.com
EVAPCO Newton
701 East Jourdan Street
Newton, IL 62448 USA
Phone: 618-783-3433
Fax: 618-783-3499
E-mail: evapcomw@evapcomw.com
H
t
EAt
rAnSfEr
S
.
ErViCES
®
: 410-756-6450 • e-
: marketing@evapco.com
mail
EVAPCO Europe
EVAPCO Europe, N.V.
European Headquarters
Industrieterrein Oost 4010
3700 Tongeren, Belgium
Phone: (32) 12-395029
Fax: (32) 12-238527
E-mail: evapco.europe@evapco.be
EVAPCO Europe, S.r.l.
Via Ciro Menotti 10
I-20017 Passirana di Rho
Milan, Italy
Phone: (39) 02-939-9041
Fax: (39) 02-935-00840
E-mail: evapcoeurope@evapco.it
EVAPCO Europe, S.r.l.
Via Dosso 2
23020 Piateda Sondrio, Italy
EVAPCO Europe, GmbH
Bovert 22
D-40670 Meerbusch, Germany
Phone: (49) 2159-69560
Fax: (49) 2159-695611
E-mail: info@evapco.de
EVAPCO Middle East DMCC
Reef Tower, 29th Level, Cluster O,
Jumeirah Lake Towers, P.O. Box 5003310
Dubai, U.A.E.
Ph: (971) 4-448 7242 - Fx: (971) 4-448 7112
info@evapco.ae
EVAPCO Air Solutions a/s
A wholly owned subsidiary of EVAPCO, Inc.
Knøsgårdvej 115
DK-9440 Aabybro Denmark
Phone: (45) 9824 4999
Fax: (45) 9824 4990
E-mail: info@flexcoil.dk
EVAPCO S.A. (Pty.) Ltd.
A licensed manufacturer of EVAPCO, Inc.
18 Quality Road
Isando 1600
Republic of South Africa
Phone: (27) 11-392-6630
Fax: (27) 11-392-6615
E-mail: evapco@evapco.co.za
Evap Egypt Engineering Industries Co.
A licensed manufacturer of EVAPCO, Inc.
5 El Nasr Road
Nasr City, Cairo, Egypt
Phone: 2 02 24022866 /2 02 24044997
Fax: 2 02 24044667 /2 02 24044668
E-mail: Primacool@link.net / Shady@primacool.net
Bulletin 123-E Metric
Service Provider
EVAPCO Asia/Pacific
EVAPCO Asia/Pacific Headq.
1159 Luoning Rd. Baoshan Ind. Zone
Shanghai, P. R. China,
Postal Code: 200949
Phone: (86) 21-6687-7786
Fax: (86) 21-6687-7008
E-mail: marketing@evapcochina.com
EVAPCO (Shanghai) Refrigeration
Equipment Co., Ltd.
1159 Louning Rd., Baoshan Industrial Zone
Shanghai, P.R. China, Postal Code: 200949
Phone: (86) 21-6687-7786
Fax: (86) 21-6687-7008
E-mail: marketing@evapcochina.com
Beijing EVAPCO Refrigeration
Equipment Co., Ltd.
Yan Qi Industrial Development District
Huai Rou County
Beijing, P.R. China, Postal Code: 101407
Phone: (86) 10 6166-7238
Fax: (86) 10 6166-7395
E-mail: evapcobj@evapcochina.com
EVAPCO Australia (Pty.) Ltd.
34-42 Melbourne Road
P.O. Box 436
Riverstone, N.S.W. Australia 2765
Phone: (61) 2 9627-3322
Fax: (61) 2 9627-1715
E-mail: sales@evapco.com.au
EvapTech Asia Pacific Sdn. Bhd
A wholly owned subsidiary of EvapTech,
Inc.
IOI Business Park, 2/F Unit 20
Persiaran Puchong Jaya Selatan
Bandar Puchong Jaya,
47170 Puchong, Selangor, Malaysia
Phone: (60-3) 8070 7255
Fax: (60-3) 8070 5731
E-mail: marketing-ap@evaptech.com
Visit EVAPCO's Websites at:
www.evapco.eu
www.mrgoodtower.eu

Advertisement

loading

Summary of Contents for EVAPCO LPT Series

  • Page 1 Contact Your Local Mr. GoodTower Service Provider ® or the EVAPCO Plant Nearest You EVAPCO, Inc. — World Headquarters & Research/Development Center EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA : 410-756-2600 • F : 410-756-6450 • e- : marketing@evapco.com hone...
  • Page 2 The LPT Series Cooling Towers, LR Series Coolers and Condensers are IBC 2012 compliant up to 1g with standard construction and up to 5.12g with additional structural modifications.
  • Page 3 Low Profile Forced Draft Towers, Coolers and Condensers The supporting “I” beams should be level to within 1/8” (3 mm) in 6’ (2 m) before setting the unit. Do not level the unit by shimming between the bottom flange and the beams as this will not provide proper longitudinal support. NOTE: Consult IBC 2012 for required steel support layout and structural design.
  • Page 4 Low Profile Forced Draft Towers, Coolers and Condensers Table 2 shows minimum “H” dimensions and gives “A” dimensions for the different unit sizes. Table 2 – Dimensional Guidelines for Lift Cables. Dimensions Refer to Drawings in Figure 2a and 2b. Coil/Casing Footprint Towers...
  • Page 5 Low Profile Forced Draft Towers, Coolers and Condensers The sealer tape should overlap on the corners as shown in Figure 4. Do not splice the sealer tape along the end flanges and preferably not on the side flanges if it can be avoided. Always remove the paper backing from the sealer tape. 1 LAYER OF SEALER CENTERED OVER THE 2 OVERLAPPING...
  • Page 6 Low Profile Forced Draft Towers, Coolers and Condensers Rigging Discharge Hoods and Discharge Attenuators Discharge Hoods may be either straight or tapered. Discharge Attenuators will be straight-sided. Both must be rigged with a separate lift after the main unit has been secured to the structural supports. The rigging for both types of accessories is shown in Figures 6a and 6b.
  • Page 7 Low Profile Forced Draft Towers, Coolers and Condensers On galvanized and stainless steel units use 5/16” (M8) nuts and bolts to secure the hood or attenuation to the casing. Con- struction details referenced in Figure 5 are shown in Figure 7 below. Figure 7 –...
  • Page 8 Low Profile Forced Draft Towers, Coolers and Condensers Table 4 – “H” Dimensions for Fan-End Sound Attenuator Assembly Coil/Casing Footprint 3’ x 6’ (0.9 x 1.8 m) 4’ (1,220 mm) 5’ x 6’ (1.5 x 1.8 m) 5’ (1,525 mm) 5’...
  • Page 9 Low Profile Forced Draft Towers, Coolers and Condensers Rigging Fan-Side Attenuators On galvanized units, the fan-side sound attenuators are secured to the main unit using 5/16” (M8) self-tapping bolts. On stainless steel units, it is secured using 1/4” (M6) threaded machine bolts which are set into rivnuts located in the side panel of the unit. Assembly is shown in Figure 10 and construction details referenced in Figure 5 are shown in Figure 11 below.
  • Page 10 Low Profile Forced Draft Towers, Coolers and Condensers Final Assembly and Start-up Details Shipping Materials - Remove any wood chocks, spare parts, or miscellaneous items that have been placed inside the unit for shipping purposes. Clean all debris from the basin. Pump Discharge Line - Connect the riser pipe from the pump discharge on the pan-fan section to the riser pipe on the coil section using the flexible connection and hose clamps provided.
  • Page 11: Freeze Protection

    The pan heaters are designed to prevent pan water from freezing when the unit is idle (no fan). If the unit will be operated dry (no water over coil) but will not be completely drained, please consult EVAPCO marketing to upsize the heaters.
  • Page 12 Phone: (32) 12 395029 • Fax: (32) 12 238527 • E-mail: evapco.europe@ evapco.be EVAPCO Europe Srl • Via Ciro Menotti 10 • I-20017 Passirana di Rho, Milano, Italy Phone: (39) 02 9399041 • Fax: (39) 02 93500840 • Email: evapcoeurope@evapco.it EVAPCO Europe GmbH •...

This manual is also suitable for:

Lrw seriesLrc series