termovana DESYRE 9.0 General Information - Warnings - Installation - Maintenance page 22

Air pellet cooker
Table of Contents

Advertisement

PROBLEM
The control
display
won't turn on
Pellets are
not reaching
the combustion
chamber
The flame
turns off and
the stove
stops
22
CAUSE
The stove is without
power
The safety fuses in the
electrical socket are blown
Faulty control display
Faulty flat cable
Faulty circuit board
Tank empty
Fire door open or pellet door
open
Clogged stove
Auger blocked by a foreign
object (such as nails)
Broken auger gearmotor
Check that there are no
"ACTIVE ALARMS" on the
display
Tank empty
Auger blocked by a foreign
object (such as nails)
Expired pellets
Pellet load value too low
"PHASE 1"
Check that there are no
"ACTIVE ALARMS" on the
display
Check that the plug is connected to the
mains.
Replace the safety fuses in the electrical
socket (3.15A-250V).
Replace the control display.
Replace the flat cable.
Replace the circuit board
Fill the tank.
Close the fire door and pellet door and check
that there are no pellet granules along the
gasket.
Clean the flue gas chamber.
Clean auger.
Replace the gearmotor.
Service the stove.
Fill the tank.
Clean auger.
Try other types of pellets.
Adjust the pellet load.
Service the stove.
09/2020 - EN
SOLUTION
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
TECHNICIAN
USER
USER
USER
USER
USER
USER
USER

Advertisement

Table of Contents
loading

Table of Contents