Download Print this page

Mitsubishi Electric FR-A800 Plus Series Installation Manuallines page 50

Hide thumbs Also See for FR-A800 Plus Series:

Advertisement

BASIC OPERATION
Parameter Name
Ethernet signal loss
*19
1431
detection function
selection
Ethernet
*19
1432
communication check
time interval
*19 Ethernet IP address 1
1434
*19 Ethernet IP address 2
1435
*19 Ethernet IP address 3
1436
*19 Ethernet IP address 4
1437
*19 Subnet mask 1
1438
*19 Subnet mask 2
1439
*19 Subnet mask 3
1440
*19 Subnet mask 4
1441
*19 Ethernet IP filter
1442
address 1
*19 Ethernet IP filter
1443
address 2
*19 Ethernet IP filter
1444
address 3
*19 Ethernet IP filter
1445
address 4
Ethernet IP filter
*19
1446
address 2 range
specification
Ethernet IP filter
*19
address 3 range
1447
specification
Ethernet IP filter
*19
1448
address 4 range
specification
Ethernet command
*19
1449
source selection IP
address 1
Ethernet command
*19
source selection IP
1450
address 2
Ethernet command
*19
1451
source selection IP
address 3
Ethernet command
*19
1452
source selection IP
address 4
Ethernet command
source selection IP
*19
1453
address 3 range
specification
*10
Differs according to types. (FM type/CA type)
*19
Available for the Ethernet models only,
44
Setting range
Initial value
0
0 to 3
9999
0 to 999.8 s, 9999
192
0 to 255
168
0 to 255
50
0 to 255
1
0 to 255
255
0 to 255
255
0 to 255
255
0 to 255
0 to 255
0
0
0 to 255
0
0 to 255
0
0 to 255
0 to 255
0
9999
0 to 255, 9999
9999
0 to 255, 9999
9999
0 to 255, 9999
0
0 to 255
0 to 255
0
0
0 to 255
0
0 to 255
9999
0 to 255, 9999
Parameter Name
Ethernet command
source selection IP
*19
1454
address 4 range
specification
*19 Keepalive time
1455
Load characteristics
1480
measurement mode
Load characteristics
1481
load reference 1
Load characteristics
1482
load reference 2
Load characteristics
1483
load reference 3
Load characteristics
1484
load reference 4
Load characteristics
1485
load reference 5
Load characteristics
1486
maximum frequency
Load characteristics
1487
minimum frequency
Upper limit warning
1488
detection width
Lower limit warning
1489
detection width
Upper limit fault
1490
detection width
Lower limit fault
1491
detection width
Load status detection
signal delay time /
1492
load reference
measurement waiting
time
1499
Parameter for manufacturer setting. Do not set.
Pr.CLR
Parameter clear
ALL.CL
All parameter clear
Err.CL
Fault history clear
Pr.CPY
Parameter copy
Initial value change
Pr.CHG
list
Automatic parameter
AUTO
setting
Group parameter
Pr.Md
setting
Setting range
Initial value
9999
0 to 255, 9999
3600 s
1 to 7200 s
0, 1, (2 to 5,
0
81 to 85)
0 to 400%, 8888.
9999
9999
0 to 400%, 8888.
9999
9999
0 to 400%, 8888.
9999
9999
0 to 400%, 8888.
9999
9999
0 to 400%, 8888.
9999
9999
*10
0 to 590 Hz
60/50 Hz
6 Hz
0 to 590 Hz
20%
0 to 400%, 9999
20%
0 to 400%, 9999
9999
0 to 400%, 9999
9999
0 to 400%, 9999
1 s
0 to 60 s
(0,) 1
0
0
(0,) 1
0
(0,) 1
0
(0,) 1 to 3
0
(0,) 1, 2

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-a820-00046-r2rFr-a820-00077-r2rFr-a820-00105-r2rFr-a820-00167-r2rFr-a820-00250-r2rFr-a820-00340-r2r ... Show all