Download Print this page

Mitsubishi Electric FR-A800 Plus Series Installation Manuallines page 36

Hide thumbs Also See for FR-A800 Plus Series:

Advertisement

BASIC OPERATION
Parameter Name
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
Up-to-frequency
41
sensitivity
Output frequency
42
detection
Output frequency
43
detection for reverse
rotation
Second acceleration/
44
deceleration time
Second deceleration
45
time
46
Second torque boost
Second V/F
47
(base frequency)
Second stall
48
prevention operation
level
Second stall
49
prevention operation
frequency
Second output
50
frequency detection
Second electronic
51
thermal O/L relay
Operation panel main
52
monitor selection
FM/CA terminal
54
function selection
Frequency monitoring
55
reference
Current monitoring
56
reference
57
Restart coasting time
58
Restart cushion time
Energy saving control
60
selection
65
Retry selection
Stall prevention
66
operation reduction
starting frequency
Number of retries at
67
fault occurrence
68
Retry waiting time
Retry count display
69
erase
*2
The setting range or initial value for FR-A820-03160(55K)-R2R or lower and FR-A840-01800(55K)-R2R or lower
*3
The setting range or initial value for FR-A820-03800(75K)-R2R or higher and FR-A840-02160(75K)-R2R or higher
*7
The value for the 200 V class.
*8
The value for the 400 V class.
*10
Differs according to types. (FM type/CA type)
*14
The setting range or initial value is for standard models.
30
Setting range
Initial value
9999
0 to 590 Hz, 9999
9999
0 to 590 Hz, 9999
0
0, 1 to 9998
10%
0 to 100%
0 to 590 Hz
6 Hz
9999
0 to 590 Hz, 9999
5 s
0 to 3600 s
0 to 3600 s, 9999
9999
9999
0 to 30%, 9999
9999
0 to 590 Hz, 9999
150%
0 to 400%
0 Hz
0 to 590 Hz, 9999
30 Hz
0 to 590 Hz
0 to 500 A,
*2
9999
9999
0 to 3600 A,
*3
9999
0, 5 to 14, 17 to
20, 22 to 36, 38,
40 to 46, 50 to 57,
0
61to 64, 67,
71 to 74, 81 to 93,
97, 98, 100
1 to 3, 5 to 14, 17,
18, 19, 21, 22, 24,
26 to 28, 30, 32 to
1
34, 36, 46, 50, 61,
*10
62, 70, 81, 82, 87
to 90, 92, 93, 97,
98
0 to 590 Hz
60/50 Hz
Inverter
*2
0 to 500 A
rated
*3
0 to 3600 A
current
0, 0.1 to 30 s,
9999
9999
1 s
0 to 60 s
0
0, 4, 9
0
0 to 5
0 to 590 Hz
60/50 Hz
0 to 10,
0
101 to 110
1 s
0.1 to 600 s
0
0
Parameter Name
Special regenerative
*14
70
brake duty
71
Applied motor
PWM frequency
72
selection
73
Analog input selection
Input filter time
74
constant
Reset selection/
disconnected PU
detection/PU stop
selection
75
Reset selection
Disconnected PU
detection
PU stop selection
Reset limit
Fault code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
Simple
Simple
Simple
80
Motor capacity
Number of motor
81
poles
*10
Motor excitation
82
current
83
Rated motor voltage
Rated motor
84
frequency
Excitation current
85
break point
Excitation current low
86
*10
speed scaling factor
Speed control gain
89
(Advanced magnetic
flux vector)
Setting range
Initial value
0 to 100%
0%
0, 1, 3 to 6, 13 to
16, 20, 23, 24, 30,
0
33, 34, 40, 43, 44,
50, 53, 54, 70, 73,
74
*2
0 to 15
2
*3
0 to 6, 25
1
0 to 7, 10 to 17
1
0 to 8
0 to 3, 14 to 17,
1000 to 1003,
*2
1014 to 1017
0 to 3, 14 to 17,
100 to 103,
14
114 to 117,
1000 to 1003,
1014 to 1017,
1100 to 1103,
*3
1114 to 1117
0 to 3
0
0, 1
1
*2
0
0
*3
0, 1
0
0 to 2
0
0 to 2
0
0 to 2
0
0 to 4, 6, 7
0.4 to 55 kW,
*2
9999
9999
0 to 3600 kW,
*3
9999
2, 4, 6, 8, 10, 12,
9999
9999
0 to 500 A,
*2
9999
9999
0 to 3600 A,
*3
9999
*7
200 V
0 to 1000 V
*8
400 V
10 to 400 Hz,
9999
9999
9999
0 to 400 Hz, 9999
9999
0 to 300%, 9999
9999
0 to 200%, 9999

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Fr-a820-00046-r2rFr-a820-00077-r2rFr-a820-00105-r2rFr-a820-00167-r2rFr-a820-00250-r2rFr-a820-00340-r2r ... Show all