Parameter Name
Power failure stop
606
external signal input
selection
Motor permissible load
607
level
Second motor
608
permissible load level
Acceleration time at a
611
restart
Reverse rotation
617
excitation current low-
speed scaling factor
Line speed bias for reel
620
change
Allowable deviation
621
from target line speed
Line speed command
622
for starting
Line speed command
added compensation
635
value voltage/current
bias
Line speed command
636
added compensation
value bias
Line speed command
added compensation
637
value voltage/current
gain
Line speed command
638
added compensation
value gain
Speed control
639
proportional term
applied diameter 1
Speed control
640
proportional term
applied diameter 2
Speed control
641
proportional gain 1
Speed control
642
proportional gain 2
Speed control
643
proportional gain 3
Speed control
644
proportional gain 4
Winding diameter
645
storage selection
Stored winding
646
diameter
Operation time with
647
stored winding
diameter
Target winding
648
diameter
Terminal 4 input
650
compensation
selection
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
Analog remote output
655
selection
*11
The increment varies depending on the Pr. 358 setting.
Setting range
Initial value
1
0, 1
150%
110 to 250%
110 to 250%,
9999
9999
0 to 3600 s,
9999
9999
9999
0 to 300%, 9999
1000 m/min
0 to 2000 m/min
*11
*11
0 to 6553.4 m/
*11
0 m/min
*11
min
0 to 6553.4 m/
*11
0 m/min
*11
min
9999
0 to 100%, 9999
0 to 6553.4 m/
9999
*11
min
, 9999
9999
0 to 100%, 9999
0 to 6553.4 m/
9999
*11
min
, 9999
1 to 99%, 9999
9999
9999
1 to 99%, 9999
9999
0 to 1000%, 9999
9999
0 to 1000%, 9999
9999
0 to 1000%, 9999
9999
0 to 1000%, 9999
0
0, 1
1 mm
1 to 6553 mm
0 s
0 to 100 s
1 mm
1 to 6553 mm
0
0, 1
0%
0 to 200%
20 Hz
0 to 120 Hz
0
0, 1, 10, 11
Parameter Name
Analog remote output
656
1
Analog remote output
657
2
Analog remote output
658
3
Analog remote output
659
4
Control circuit
663
temperature signal
output level
Regeneration
665
avoidance frequency
gain
Power failure stop
668
frequency gain
SF-PR slip amount
673
adjustment operation
selection
SF-PR slip amount
674
adjustment gain
User parameter auto
675
storage function
selection
679
Second droop gain
Second droop filter
680
time constant
Second droop function
681
activation selection
Second droop break
682
point gain
Second droop break
683
point torque
Tuning data unit
684
switchover
686
Maintenance timer 2
Maintenance timer 2
687
warning output set
time
688
Maintenance timer 3
Maintenance timer 3
689
warning output set
time
Deceleration check
690
time
Second free thermal
692
reduction frequency 1
Second free thermal
693
reduction ratio 1
Second free thermal
694
reduction frequency 2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
707
Motor inertia (integer)
Motor inertia
724
(exponent)
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
BASIC OPERATION
Setting range
Initial value
800 to 1200%
1000%
1000%
800 to 1200%
1000%
800 to 1200%
1000%
800 to 1200%
0 °C
0 to 100 °C
100%
0 to 200%
0 to 200%
100%
9999
2, 4, 6, 9999
100%
0 to 500%
9999
1, 9999
9999
0 to 100%, 9999
9999
0 to 1 s, 9999
0 to 2, 10, 11, 20
9999
to 22, 9999
0.1 to 100%,
9999
9999
0.1 to 100%,
9999
9999
0
0, 1
0
0 (1 to 9998)
9999
0 to 9998, 9999
0
0 (1 to 9998)
9999
0 to 9998, 9999
1 s
0 to 3600 s, 9999
9999
0 to 590 Hz, 9999
100%
1 to 100%
0 to 590 Hz, 9999
9999
100%
1 to 100%
9999
0 to 590 Hz, 9999
9999
5 to 50 ms, 9999
9999
10 to 999, 9999
0 to 7, 9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
37