Overview Of Connections, Bg5 And Bg6A - Keba ServoOne Series Operation Manual

Multi-axis system with sinusoidal regeneration
Hide thumbs Also See for ServoOne Series:
Table of Contents

Advertisement

Electrical installation
ID no.: 1101.21B.6-00 Date: 04/2020
4.3.3

Overview of connections, BG5 and BG6a

1
2
D
D
,
1
2
T
T
,
Service
USB 1.1
2
X
interface
Service
Ethe rnet
3
X
interface
Control
4
X
3
ISA00+
4
ISA00-
5
ISA01+
6
ISA01-
15
ISD00
16
ISD01
17
ISD02
18
ISD03
19
ISD04
20
ISD05
21
ISD06
ENPO
10
ENPO
22
ISDSH
12
RSH
11
23
Relais
24
OSD04
7
OSD00
8
OSD01
9
OSD02
1
DGND
2
+24V(U
)
H
14
13
DGND
KTY temp. sensor
5
X
for set-up reactor
Communication
Option 1
Fieldbusses
Figure 4.6 Overview of connections, BG5 and BG6a
11
X
+
DC-link
(BG 6a protected)
Danger!
+
1
24 V DC Supply for
10
X
2
+
control electronic (U
)
1
9
X
V
2
21
X
L1
Mains synchronization
L2
and pre-Charging
L3
N
Danger!
Mains contactor
HREL
Top
24 V bridge only for
SO Supply unit BG5
Bottom
12
RB+
X
Braking resistor
RB−
ZK−
DC-link
ZK+
L3
Mains supply
L2
L1
Danger!
Operation Manual ServoOne Supply Unit
No.
Designation
D1, D2
7-segment display
Device state indication
T1, T2
Button
Service functions
Optional module for field bus e.g.
Option 1
Communication
SERCOS, PROFIBUS-DP, EtherCAT or
CANopen
Service interface, Plug & Play connection
X2
USB 1.1 interface
to PC
Service interface,
X3
Ethernet interface
fast TCP/IP connection (RJ45)
8 digital inputs, 3 digital outputs,
X4
Control connections
1 additional relay output
Connection for tempera-
X5
KTY temperature sensor for step-up choke
ture monitoring
Connection for control
Supply voltage for the servocontroller control
X10, X9
supply U
electronics, 24 V DC
V
Connection for DC power supply (BG6a
X11
DC power supply
protected),
PE connection
AC mains connection (supply and
regeneration),
PE connection with shield plate,
X12
Power connection
braking resistor,
(connection for DC power supply, supply
unit BG6a to ServoOne DC axis controller
BG6, 6a)
Connection for mains
Mains synchronisation,
synchronisation/
X21
DC link precharging, switching on mains
DC link precharging;
after precharging
auxiliary relay
SW, HW
Rating plates
Rating plates for software and hardware
Shield connection to
Possible via shield plate (optional)
earth
Table 4.1 Key to overview of connections, BG5 and BG6a
34
Function
Page
p. 67
p. 66
p. 54
p. 54
p. 54
p. 51
p. 44
p. 48
p. 40
p. 46
p. 40
p. 54
p. 50
p. 45
p. 33
-

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ServoOne Series and is the answer not in the manual?

Table of Contents

Save PDF