Western Digital 2U24 Installation Manual
Western Digital 2U24 Installation Manual

Western Digital 2U24 Installation Manual

Flash storage platform
Hide thumbs Also See for 2U24:

Advertisement

Quick Links

Installation
Guide
2U24 Flash Storage Platform
Regulatory Model: G224-J-12
March 2020
Rev. 1.4
1ET0280

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2U24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Western Digital 2U24

  • Page 1 Installation Guide 2U24 Flash Storage Platform Regulatory Model: G224-J-12 March 2020 Rev. 1.4 1ET0280...
  • Page 2: Table Of Contents

    Power Connections................................... 9 Power Cords....................................9 Safety and Service................................... 10 Chapter 4. Installation Process..............................11 2U24 Flash Storage Platform Packaging Overview........................12 Unpacking Procedure................................13 2U24 Flash Storage Platform Installation Overview....................... 13 2U24 Flash Storage Platform Specification Summary....................13 Rack Requirements................................14 Installation Process................................... 15...
  • Page 3: Revision History

    2. Added the packaging image to the packaging overview. See Installation Process (page 15) May 2017 Revision 1.2 Changed the product name from "2U24 All-Flash Storage Platform" to "2U24 Flash Storage Platform" April 2019 Revision 1.3 Updated rack depth requirement. See...
  • Page 4: Points Of Contact

    Points of Contact Points of Contact For further assistance with a Western Digital product, contact Western Digital Datacenter Platforms technical support. Please be prepared to provide the following information: part number (P/N), serial number (S/N), product name and/or model number, and a brief description of the issue.
  • Page 5: Notices

    Per Western Digital Terms and Conditions of Sale, the user of Western Digital products in life support applications assumes all risk of such use and indemnifies Western Digital against all damages.
  • Page 6: Chapter 1. Disclaimers

    Learn about the Regulatory, Safety, and Electromagnetic standards for which this product is compliant. The following chapter describes the Regulatory Statement of Compliance, Safety Compliance, and Electromagnetic Compatibility Agency Requirements for the 2U24 Flash Storage Platform. In This Chapter: - Regulatory Statement........2...
  • Page 7: Regulatory Statement

    1.1.1   Restricted Access Location The 2U24 Flash Storage Platform is intended for installation in a server room or computer room where at least one of the following conditions apply: • access can only be gained by service persons or by users who have been instructed about the restrictions applied to the location and about any precautions that shall be taken and/or •...
  • Page 8: Country Certifications

    1. Disclaimers Installation Guide 1.1 Regulatory Statement • CE – EMC Directive 2014/30/EU • VCCI V-3 • BSMI CNS14338 • KN32 • AS/NZS CISPR 32 • TR CU 020/2011 Immunity • EN 61000-3-2 Harmonic Current Emissions • EN 61000-3-3 Voltage Fluctuations and Flicker •...
  • Page 9: Chapter 2. Regulatory

    Western Digital Regulatory In This Chapter: - FCC Class A Notice........5 - ICES-003 Class A Notice—Avis NMB-003, Classe A............5 - Europe (CE Declaration of Conformity)..5 - Japanese Compliance Statement, Class A ITE..............5 - Taiwan Warning Label Statement, Class A...
  • Page 10: Fcc Class A Notice

    Any modifications made to this device that are not approved by Western Digital may void the authority granted to the user by the FCC to operate equipment.
  • Page 11 2. Regulatory Installation Guide 2.5 Taiwan Warning Label Statement, Class A ITE English translation: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take adequate measures.
  • Page 12: Chapter 3. Safety

    Western Digital Safety In This Chapter: - Optimizing Location........8 - Safety Warnings and Cautions......8 - Electrostatic Discharge......... 8 - Rackmountable Systems........9 - Power Connections........9 - Power Cords........... 9...
  • Page 13: Optimizing Location

    3.3   Electrostatic Discharge CAUTION Electrostatic discharge can harm delicate components inside Western Digital products. Electrostatic discharge (ESD) is a discharge of stored static electricity that can damage equipment and impair electrical circuitry. It occurs when electronic components are improperly handled and can result in...
  • Page 14: Rackmountable Systems

    3.4   Rackmountable Systems CAUTION Always install rack rails and storage enclosure according to 2U24 Flash Storage Platform product documentation. Follow all cautions, warnings, labels, and instructions provided within the rackmount instructions. Reliable grounding of rack-mounted equipment should be maintained.
  • Page 15: Safety And Service

    All maintenance and service actions appropriate to the end-users are described in the product documentation. All other servicing should be referred to an Western Digital-authorized service technician. To avoid shock hazard, turn off power to the unit by unplugging both power cords before servicing the unit.
  • Page 16: Chapter 4. Installation Process

    Western Digital Installation Process The following chapter provides installation information for the 2U24 Flash Storage Platform. In This Chapter: - 2U24 Flash Storage Platform Packaging Overview............12 - Unpacking Procedure........13 - 2U24 Flash Storage Platform Installation Overview............13 - Installation Process........15...
  • Page 17: 2U24 Flash Storage Platform Packaging Overview

    4.1   2U24 Flash Storage Platform Packaging Overview The 2U24 Flash Storage Platform packaging comes in four separate boxes, all of which are contained in one outer box. The following image shows the layout of each box, and the table that follows it lists the contents of each package.
  • Page 18: Unpacking Procedure

    Philips Head Screwdriver For attaching rails. Once the system is unpacked and all components are accounted for, the installation of the 2U24 Flash Storage Platform can begin. Start by assembling the rails by adding the tensioning spring and then install them in the rack.
  • Page 19: Rack Requirements

    Rack spaces should be equipped to give the enclosure ample power and connectivity to perform as expected. They must also provide effective airflow, cooling , and allow for access for routine maintenance. For proper rack installation of the 2U24 Flash Storage Platform, mount the enclosure according to the following drawing:...
  • Page 20: Installation Process

    Step 1 : Attach the tensioning springs to each rail. a. Locate the tensioning springs in the kit's packaging. The 2U24 Flash Storage Platform rail kits come with two tensioning springs in the box that need to be attached for the rails to function properly.
  • Page 21 4. Installation Process Installation Guide 4.4 Installation Process d. Attach one end of the tensioning springs to each rivet. Step 2 : Install the rails into the rack. a. Rotate the clips at the front and rear ends of the rail to reveal the rail posts.
  • Page 22 4. Installation Process Installation Guide 4.4 Installation Process b. From the front of the rack, orient the rail so that the shelf is facing the interior of the rack, and the collabsible end is facing the rear of the rack. c.
  • Page 23 4. Installation Process Installation Guide 4.4 Installation Process g. Complete the same sequence for the other rail. Step 3 : Install the chassis into the rails. a. Orient the chassis such that the PSU and ESM bays are facing the inside of the rack. b.
  • Page 24 4. Installation Process Installation Guide 4.4 Installation Process c. Complete these steps for each cable until all are installed. d. When there is power running to the platform, the activity LED at the back of the ESM will turn on and remain solid if there is no IO to the drives. This will ensure that it is installed correctly.
  • Page 25 4. Installation Process Installation Guide 4.4 Installation Process Figure 4: Cinching Cable Retention Clip Step 9 : Wait 2 minutes for the system to run through its power up sequence. The system is now ready for operation.