Room Temperature Control For Wired Remote Controller Sensor; Room Temperature Sensor Switching - Fujitsu ASTG18KMTC Service Instruction

Split type room air conditioner wall mounted type inverter
Hide thumbs Also See for ASTG18KMTC:
Table of Contents

Advertisement

1-3. Room temperature control for wired remote controller sensor

Depending on the installed environment, correction of the wire remote temperature sensor may be required.
Select the approriate control drtting according to the installed environment.
To change this setting, set Function 42 to Both "01".
Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
No correcion 00°C
More
Cooling
Less
Heating
Less
Cooling
More
Heating
1-4. Auto Restart
Enable or disable automatic restart after a power interruption.
Setting Description
Enable
Disable
* Auto restart is an emergency function such as for power outage etc. Do not attempt to
use this function in normal operation. Be sure to operate the unit by remote controller or
other external input device.
1-5. Room temperature sensor switching (Only for Wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
Setting Description
Indoor unit
Both
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
Setting Description
No correcion
-0.5°C
-1.0°C
-1.5°C
-2.0°C
-2.5°C
-3.0°C
-3.5°C
-4.0°C
+0.5°C
+1.0°C
+1.5°C
+2.0°C
+2.5°C
+3.0°C
+3.5°C
+4.0°C
Function Number
40
Function Number
42
03-02
(
Factory setting)
Function Number
Setting Value
35
36
(For
(For
cooling)
heating)
(
Factory setting)
Setting Value
00
01
(
Factory setting)
Setting Value
00
01
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17

Hide quick links: