General Information; Optional Parts; Wired Remote Controller; Troubleshooting - Fujitsu AIRSTAGE ASTH18CNTA Operation Manual

Table of Contents

Advertisement

Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Consult
authorized service personnel in order to use this function.
Clean the air filter when the indicator lamp shows the
)
following:
Indicator lamp
Blinks 3 times, at intervals of 21 seconds
After cleaning, reset the filter indicator by pushing
for 2 seconds or less. (Refer to page 3.)

11. GENERAL INFORMATION

■ Auto-restart function
In event of power interruption such as a blackout, the air conditioner
stops once. But it restarts automatically and performs previous operation
when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of
the timer will be reset.
After the power supply is resumed, [
blinks to notify you that there has been a timer fault. In such a case,
reset the clock and timer settings.
■ Malfunctions caused by other electrical
devices
Use of other electrical appliances such as an electric shaver or nearby
use of a wireless radio transmitter may cause the malfunction of the air
conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
■ Temperature and humidity range
Permissible ranges of temperature and humidity are as follows:
Cooling/Dry mode
Outdoor
temperature
Indoor
temperature
Indoor humidity [%] 80 or less *
*1) Suction temperature of the outdoor unit.
*2) If the air conditioner is used continuously for many hours, water may
condense on the surface and drip.
• If the unit is operated under the conditions except the permissible
temperature range, the air conditioner operation may stop because
of the automatic protection circuit working.
• Depending on the operating conditions, the heat exchanger may
freeze, causing water leakage or other malfunction (in the Cooling
or Dry mode).
■ Other information
• Do not use the air conditioner for any purpose other than room
cooling/dry or fan.
Blinking pattern
on the indoor unit
] indicator on the indoor unit
1)
[°C]
10 to 50 *
[°C]
18 to 32
2)

12. OPTIONAL PARTS

12.1. Wired remote controller

The optional wired remote controller can be used.
You can use wired and wireless remote controller together.
However, some functions of the wireless remote controller are
restricted. If you set the restricted functions, beeping sound will be
heard, [ ], [
], and [
] indicators on the indoor unit will blink.
<Restricted functions for wireless remote controller>
When using together with wired remote controller (2-wire)
• Powerful operation
Group control
One remote controller can control up to 16 air conditioners. All of the air
conditioners will be operated with the same settings.

13. TROUBLESHOOTING

In the following events, immediately stop operation of
the air conditioner, and disconnect all the power supply
by turning off the electrical breaker or disconnecting
the power plug. Then consult your dealer or authorized
service personnel.
As long as the unit is connected to the power supply, it
is not insulated from the power supply even if the unit is
turned off.
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Does not operate at all.
□ Has there been a power outage?
In this case, the unit restarts automatically after the power supply
is resumed. (Refer to page 9.)
□ Has the circuit breaker been turned off?
⇒ Turn on the circuit breaker.
□ Has a fuse blown out or the circuit breaker been tripped?
⇒ Replace the fuse or reset the circuit breaker.
□ Is the timer operating?
⇒ To check or deactivate the timer setting, refer to page 5.
Poor cooling performance.
□ Is the unit operating under the conditions except the permissible
temperature range?
In this case, the air conditioner may stop because of the automatic
protection circuit working.
□ Do you have an arrangement with your electric company for
Demand Response?
In this case, the air conditioning performance may become lower
or the operation may stop. (Refer to page 6.)
□ Is the air filter dirty?
⇒ Clean the air filter. (Refer to page 7.)
□ Is the intake grille or outlet port of indoor unit blocked?
⇒ Remove the obstructions.
□ Is the room temperature adjusted appropriately?
⇒ To change the temperature setting, refer to page 5.
□ Is a window or door left opened?
⇒ Close the window or the door.
□ Is the fan speed set to Quiet?
⇒ To change the fan speed, refer to page 5.
□ <In the Cooling mode> Is direct or strong sunlight shining into the
room?
⇒ Close the curtains.
□ <In the Cooling mode> Are there other heating apparatus or com-
puters operating, or too many people in the room?
⇒ Turn the heating apparatus or computers off, or set the tem-
perature lower. (Refer to page 5.)
En-9