Installation Options - Trane X13511538-01 Installation And Operation Manual

Touch-screen programmable thermostat
Table of Contents

Advertisement

Installation Options

Table 7.
Installer configuration setup menu
Opt.
Name
Def
No.
0100
Temperature indication/
0
Resolution
0110
Clock Format
12
0120
Year
11
Month
1
0121
0122
Day
1
0125
Daylight Savings
2
• Spring Ahead Month
• 03
0126
0127
• Spring Ahead Day
• 01
0128
• Fall Back Month
• 11
0129
• Fall Back Day
• 01
0130
System Selection
8
0140
Schedule Options
1
0150
TOD/Economizer Output
0
(Terminal A)
0151
Heat Fan Operation
0
Reversing Value O/B
0
0153
0160
Cycles Per Hour (CPH)
3
[First Stage Compressor]
CPH (Second Stage
3
0161
Compressor)
Values/Descriptions
• 0= °F, 1 degree resolution
• 3= °C with 0.5 degree resolution
• 1= °F, 0.5 degree resolution
• 4= °C with 0.1 degree resolution
• 2= °C, 1 degree resolution
• 12= 12-hour clock
• 24= 24-hour clock
• 11–99
• 1–12
• 1–31
• 0= Disabled
• 3= Europe, changeover at 1:00am
• 1= US (1987), changeover at
• 4= Manual, changeover at 2:00am
2:00am
• 2= US (2007), changeover at
2:00am
• 01-12
• 01-31
• 01-12
• 01-31
• 1= 1H/1C (Conv) 1st Stage Heat
• 7= 2H/2C (Conv) 1st & 2nd Stage
(W), 1st Stage Comp (Y), Fan (G)
Heat (W,W2), 1st & 2nd Stage Comp
• 2= 1H/1C (HP) 1st Stage Comp (Y),
(Y,Y2), Fan (G)
Changeover (O/B), Fan (G)
• 8= 2H/1C (Conv) 1st & 2nd Stage
• 3= 1H (Conv) 1st Stage Heat (W),
Heat (W,W2), 1st Stage Comp (Y),
without fan
Fan (G)
• 4= 1H (Conv) 1st Stage Heat (W),
• 9= 1H/2C (Conv) 1st Stage Heat
Fan (G)
(W), 1st & 2nd Stage Comp (Y,Y2),
• 5= 1C (Conv) 1st Stage Comp (Y),
Fan (G)
Fan (G)
• 10= 2H/2C (HP) 1st & 2nd Stage
• 6= 2H/1C (HP) 1st Stage Comp (Y),
Comp (Y,Y2), Changeover (O/B), Fan
Changeover (O/B), Auxiliary Heat
(G)
(W1), Fan (G)
• 11= 3H/2C (HP) 1st & 2nd Stage
Comp (Y,Y2), Changeover (O/B),
Auxiliary Heat (W1), Fan (G)
0=Non-programmable
1= Programmable
• 0= Unused
• 2= Economizer energizes terminal A
• 1= TOD energizes terminal A during
during a call for cool.
occupied period, not during
unoccupied period.
0= System controls fan
1= Thermostat controls fan
0= O/B ON when call for cool
1= O/B ON when call for heat
1–5
1–5
Notes
This setting affects indoor temperature display and setpoint display
resolutions. Outdoor temperature display area is always ±1 resolution
for both F and C. Refer to Option 0210.
Available year range: 2011–2099. This value is updated to the real time
clock after setting. Day of the week is updated automatically.
This value is updated to the real time clock after setting. Day of the week
is updated automatically.
Month dependent: this value is updated to the real time clock after
setting. Day of the week is updated automatically.
Options available only if 0125 is set to 4.
TOD is not available in Non-programmable Mode. (Refer to Option 0140)
Only shown for conventional system with heat stages and fan capability.
For heat pump, the fan relay operates with thermostat control.
Only shown for heat pump systems.
Only for systems with cool or HP stage. (Refer to Option 0130.) Selection
in this stage changes 2nd stage cool default CPH.
Only for systems with 2-cool or HP stages. (Refer to Option 0130.)