Motor/Gear Reducer - Graco E-Flo EP G Series Repair Parts

4-ball pumps with sealed or open wet cup lowers
Table of Contents

Advertisement

Repair

Motor/Gear Reducer

Motor Removal
1. Follow the Pressure Relief Procedure, page 7.
2. Shut off electrical power to the unit.
NOTE: See F
. 22 for all NEMA 182/184 TC Frame
IG
electric motors. See F
IG
100L/B5 Frame electric motors.
3. While one person supports the motor (19), remove
the screws (37). Pull the motor away from the gear
reducer.
NOTE: If the motor does not come off the gear reducer
easily, stop immediately and go to Motor/Coupler is
Difficult to Remove, page 29.
4. See F
. 24. Loosen both setscrews (31). Insert the
IG
coupler removal tool (T) into the coupler (28). Turn
nut clockwise until tight, then pull the coupler off the
gear reducer input shaft (105) by turning hex-head
screw (HS) clockwise.
31
19
Motor Rotation
(counter-clockwise as viewed from fan end)
F
. 22. All NEMA 182/184 TC Frame Electric Motors
IG
28
. 23 for IEC 112M/B5 and
37
1
20
31
28
NOTE: A faint clicking may be heard while the motor is
running. This is normal and is due to necessary clear-
ances between the coupler (28), motor shaft, and motor
key. If the intensity increases significantly over time, it
could indicate the coupler is wearing and should be
replaced. Do not open the gear reducer. Opening the
gear reducer voids the warranty. The gear reducer is
not field serviceable beyond the maintenance recom-
mended in this manual.
19
(counter-clockwise as viewed from fan end)
F
. 23. IEC 112M/B5 and 100L/B5 Frame Electric
IG
Motors
ti8726b
31
MA
MS
Motor Rotation
37
1
20
28
ti9007b
3A3386E

Advertisement

Table of Contents
loading

Table of Contents