8-2. External output

With using external output function, operating status of this product can be transmitted to the exter-
nal device, and also, this product can be inter-connected with the external device.
¢ Operation status output
 Circuit diagram example
Indoor unit
control PCB
• *: Make the distance from the PCB to the connected unit within 10 m.
• Relay spec: Max. DC 24 V, 10 mA to less than 500 mA.
Indoor unit
Output signal
 Optional part
Part name
External connect kit
Communication kit
* For operating the external function, the wall mounted type requires the communication kit in
addition to the wire (UTY-XWZXZ5).
8-2. External output
Communication kit
Connector
DC 24 V
1
2
10 m*
Optional parts
Operation
Stop
On
Off
Model name
UTY-XWZXZ5
UTY-TWBXF1
Example: Relay unit
V
Signal
Locally purchased
- 20 -
Connected unit
Example: Display
Relay
power supply
Exterior
External output wire