7. Safety devices
Type of
protection
Circuit protection
Current fuse (PCB*)
Thermal
Fan motor
protector
protection
program
*PCB: Printed Circuit Board
Protection form
ASYG09KHCA
Activate
Reset
Model
ASYG12KHCA
250 V, 3.15 A
150 ±15°C
Fan motor stop
120 ±15°C
Fan motor restart
- 16 -
ASYG14KHCA
7. Safety devices