Important Safety Information; Insert Safety Certification; Insert Emissions Certification; Btu & Efficiency Specifications - Vermont Castings MONTPELIER II MONTP-II-CB Installation Manual

Montpelier ii wood insert
Table of Contents

Advertisement

1 1

Important Safety Information

A. Insert Safety Certification
Model Number: MONTP-II-CB & MONTP-II-BM
Laboratory: OMNI Test Laboratories, Inc.
Report Number:
0061WN100S
Type:
Solid Fuel Type, Listed Room Heater
UL1482-2011 and ULC S628-93
Standard:
and (UM) 84-HUD.
B. Insert Emissions Certification
Model Number: MONTP-II-CB & MONTP-II-BM
Laboratory: OMNI Test Laboratories, Inc.
Report Number: 0061WN100E
Standard: UL1482-2011
Can be found at:
www.vermontcastings.com/about-us/epa-certification
The MONTP-II-CB & MONTP-II-BM is
Certified to comply with 2020 crib wood
particulate emission standards.
This wood appliance needs periodic inspection and repair
for proper operation. Consult the owner's manual for further
information. It is against federal regulations to operate this
wood appliance in a manner inconsistent with the operating
instructions in the owner's manual.
NOTE: This installation must conform with local codes.
In the absence of local codes you must comply with the
UL1482-2011, (UM) 84-HUD and NPFA211 in the U.S.A.
and the ULC S628-93 and CAN/CSA-B365 Installation
Codes in Canada. NOT APPROVED FOR MOBILE
HOME INSTALLATIONS IN CANADA!
Approved for ZC fireboxes.
3
C. BTU & Efficiency Specifications
EPA Certification
EPA Certified Emissions: 1.9 grams per hour
*LHV Tested Efficiency: 77.0%
**HHV Tested Efficiency: 71.3%
***EPA BTU Output: 24,700 to 26,800 / hr
****Peak BTU/Hour
Firebox Size: 2.37 cubic feet
Recommended Wood
* Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. LHV assumes the moisture
is already in a vapor state so there is no loss in energy
to vaporize.
** Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests in accordance with the
requirements of CSA B415.1. HHV includes the energy
required to vaporize the water in the fuel.
*** A range of BTU outputs calculated using HHV Efficiency
and the burn rates from the EPA tests, using Douglas Fir
dimensional lumber.
**** A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efficiency.
7101-802G
Number: 199-19
Number:
56,000
Output:
Vent Size: 6 inches
20 inches
Length:
Fuel Seasoned Cord Wood
07/20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Montpelier ii montp-ii-bm

Table of Contents