Control Commands - HP 4934A Operating And Calibration Manual

Transmission impairment measuring set
Table of Contents

Advertisement

Control Commands
Control commands change the 4934A's operation. Control commands emulate a
front-panel key; sending a command is comparable to pressing the corresponding
key. Another set of commands (query commands) retrieve results from the unit
(see
Query Commands,
page 7-8).
When the 4934A accepts a command it returns OK to the controller. Unknown
commands cause the unit to return ERR. Inappropriate commands are ignored.
HP
4934A
TIMS Remote Control Commands
Command
Description
RESET
Resets unit to power on condition.
RMT
Puts unit into remote mode, disable front panel.
LCL
Returns unit to front-panel (local) control.
TRMT
Same as pressing the TRMT key.
RCV
Same as pressing the RCV key.
NORM
Sets input jacks to TRMT-RCV configuration (as with REVERSE key).
REV
Sets input jacks to RCV-TRMT configuration (as with REVERSE key),
1135
Sets Tx Impedance to 135 ohms (as with the TRMT key).
T150
Sets Tx Impedance to 150 ohms.
T600
Sets Tx Impedance to 600 ohms.
T900
Sets Tx Impedance to 900 ohms.
T1200
Sets Tx Impedance to 1200 ohms.
R135
Sets Rx Impedance to 135 ohms (as with the RCV key).
R150
Sets Rx Impedance to 150 ohms.
R600
Sets Rx Impedance to 600 ohms.
R900
Sets Rx Impedance to 900 ohms.
R1200
Sets Rx Impedance to 1200 ohms.
Remote Control
7-5

Hide quick links: