Operation; Maintenance; Troubleshooting - Sealey DEH2001 Manual

Industrial fan heater
Table of Contents

Advertisement

4.1.4.
connect the other end of the extension cable to the mains supply.

5. OPeratIOn

5.1.
Position the fan heater so that it stands upright on a firm surface and at a safe distance from wet environments and flammable
objects.
WarnInG! always allow elements to cool before moving the units. use only on a smooth even surface.
5.2.
connect the fan heater to the mains (see section 4 for deh10001).
5.3.
set the thermostat knob to the MaX and let the heater operate at full power.
5.4.
the fan heater will switch on when the heating selector is set to one of the power settings.
5.5.
once the room reaches the required temperature, the heating element will stop working but the fan will keep working. once the room
temperature goes below the set temperature, the heating element will start working. the fan heater will start and stop automatically
keeping the room temperature constant.
5.6.
before switching off the heater, please turn the thermostat to Min position and turn the switch to the fan position, let the appliance
cool down for two minutes then turn off the heater and pull out the plug.
Off
Fan
Full Power

6. MaIntenanCe

WarnInG! before cleaning the appliance, disconnect it from the mains and let it cool down.
6.1.
the cover can easily get dirty, wipe it often with a soft cloth. to clean dirt off of the cover, wipe with a clean sponge dipped in <50°c
water and mild detergent, then dry the heater cover with a clean cloth. be careful not to let water enter the appliance.
dO nOt splash water onto the heater, never use solvent like gasoline etc. to clean the heater, in order to protect the cover.
8
6.2.
When you store the heater, let it cool down first, keep it dry. Then cover it with a plastic bag, put in a packing box and store it in a
dry, ventilated place.

7. trOublesHOOtInG

problem
the heater does not operate,even when it
is plugged in and the switch and thermostat
are switched on.
the heating element is glowing
the appliance didn't heat up, or only the fan
worked
abnormal noise
© Jack sealey limited
fig.1
possible cause
the plug is loose, or there is a bad
connection
no power in socket outlet
the input voltage is too high or too low
the air inlet grill is blocked
the switch was not turned to a heat setting
the thermostat operated
the self-resetting cut-out operated
the appliance is not stood upright
Original Language Version
Off
Fan
Half Power
Full Power
treatment
pull out the plug, check the connection of
the plug and socket.
insert the plug in a proper socket
use power supply according to the rating on
the label
Keep the heater away from articles like
curtains, plastic bags, paper and other
things that can cover the inlet or can easily
cover the air inlet
turn the switch to heat setting
turn the thermostat down wait for it to cool
and then turn the thermostat up. if there is
no click and the thermostat is not damaged,
the heater will automatically switch on when
the appliance has cooled down
turn the heater off and inspect the blockage
of inlet or outlet. disconnect the plug and
wait at least 10 minutes for the protection
system to reset before attempting to restart
the heater.
put the heater on a level surface
deh2001 deh3001 deh5001 deh10001 issue 1 23/08/19
fig.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deh3001Deh5001Deh10001

Table of Contents