PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood.

TABLE OF CONTENTS

Product warranty ................................................ 1
1
Introduction ............................................. 1
2
Specifications/Approvals ......................... 2
2.1 Enclosure ..................................................... 2
2.2 Switch ........................................................... 2
2.3 Approvals ...................................................... 2
3
Theory of Operation ................................. 2
4
Installation ............................................... 2
4.1 Unpacking..................................................... 2
4.2 Mounting the switch .................................... 3
4.3 Wiring connection ........................................ 3
5
Set-up ...................................................... 4
5.1 Initial test ...................................................... 4
6
Pump-Control Set-up .............................. 4
6.1 Interval relay wiring ..................................... 4
7
Troubleshooting ...................................... 4
7.1 Introduction .................................................. 4
7.2 Switch test .................................................... 4
7.3 Actuation test ............................................... 4
8
Telephone Assistance .............................. 5
9
Interval Relay .......................................... 9
9.1 Operation ...................................................... 9
9.2 Typical applications ..................................... 9
9.3 Connection diagram .................................... 9
Emerson.com/FinalControl
Tables and Figures
Figure 1 - MGS-314 Series ................................ 3
Figure 2 - MGS-314D Series ............................. 3
Figure 3 - Control drawing CSA approved
explosion-proof for
MGS-314/314D (7E741-009) ............. 5
Figure 4 - Control drawing CSA approved
intrinsically safe for
MGS-314/314D (7E742-009) ............. 6
Figure 5 - Control drawing ATEX/IECEx
certified explosion-proof for
MGS-314/314D (7E741-010) ............. 7
Figure 6 - Control drawing ATEX/IECEx
certified intrinsically safe for
MGS-314/314D (7E742-010) ............. 8
Figure 7 - Application 1-Pump-up diagram ..... 9
Figure 8 - Application 2-
Pump-down diagram ........................ 9
Figure 9 - Connection diagram ......................... 9

PRODUCT WARRANTY

Emerson warrants its Penberthy products
as designed and manufactured to be free of
defects in material and workmanship for a
period of one year after the date of installation
or eighteen months after date of manufacture,
whichever is earliest. Emerson will, at its
option, replace or repair any products which
fail during the warranty period due to defective
material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to Emerson, with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or altered outside of the Emerson factory, or
if it has been subjected to misuse, neglect
or accident.
© 2019 Emerson. All Rights Reserved.
Emerson's responsibility hereunder is
limited to repairing or replacing the product
at its expense. Emerson shall not be liable
for loss, damage, or expenses directly or
indirectly related to the installation or use
of its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
building, property or persons, by reason of the
installation or use of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless modified or
made in writing and signed by the company's
president or a vice president.

1 INTRODUCTION

The instructions in this manual pertain to
the Penberthy Model MGS-314 or MGS-314D
magnetic level meter switch.
The Model MGS-314/314D Series magnetic
level meter switch is designed to detect the
passage of the float in a MULTIVIEW™ magnetic
liquid level meter, at a specific location. The
switch consists of a snap-action switch and
a magnetic actuation assembly encased
in a watertight (Type 4) or explosion-proof
(Type 7) enclosure.
VCIOM-03387-EN 20/06

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Penberthy MGS-314 Series

  • Page 1: Table Of Contents

    MGS-314/314D (7E741-010) ..... 7 Figure 6 - Control drawing ATEX/IECEx This is Emerson's sole warranty and in lieu of certified intrinsically safe for all other warranties, expressed or implied which TABLE OF CONTENTS MGS-314/314D (7E742-010) .....
  • Page 2: Specifications/Approvals

    PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 2 SPECIFICATIONS/APPROVALS 2.1 Enclosure Watertight (Type 4) and explosion-proof (Type 7) cast aluminum housing; NBR O-ring 2.2 Switch Output: MGS-314 Series: SPDT (Form C) switch output: 5 amps at Vac, non-inductive load MGS-314D Series: DPDT (2x Form C) switch output: 10 amps at Vac, non-inductive load...
  • Page 3: Mounting The Switch

    PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Figure 1 MGS-314 SERIES Toggle Toggle Position 'A' Position 'B' Figure 2 MGS-314D SERIES Toggle Toggle Position 'A' Position 'B' 4.2 Mounting the switch 4.3 Wiring connection 5.
  • Page 4: Set-Up

    PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 5 SET-UP DANGER! Energizing the switch with the cover removed can cause ignition of flammable materials or atmospheres, resulting in personal injury, death or property damage. Do not apply power to the switch while performing these tests.
  • Page 5: Telephone Assistance

    PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 8 TELEPHONE ASSISTANCE Figure 3 CONTROL DRAWING CSA APPROVED EXPLOSION-PROOF FOR MGS-314/314D (7E741-009) If you are having problems with your Penberthy level meter switch, notify your HAZARDOUS AREA NON-HAZARDOUS AREA local Penberthy distributor, or call the factory...
  • Page 6 PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Figure 4 CONTROL DRAWING CSA APPROVED INTRINSICALLY SAFE FOR MGS-314/314D (7E742-009) TWO WIRE ENTITY CONTROL DRAWING HAZARDOUS AREA NON-HAZARDOUS AREA Use CSA certified safety barriers: CLASS I DIV 1 GROUP A, B, C, D CLASS II DIV 1 GROUP E, F, G CLASS III DIV 1...
  • Page 7 PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS - APPENDIX A Figure 5 CONTROL DRAWING ATEX/IECEx CERTIFIED EXPLOSION-PROOF FOR MGS-314/314D (7E741-010) HAZARDOUS AREA NON-HAZARDOUS AREA EX d IIB Models MGS-314-A MGS-314D-A MGS-314L-A A flame path seal-off shall be installed directly to threaded entry of enclosure Wiring to be in accordance with National Electric Code (NEC) pertinent parts of the 500 series of Article 5 or local codes as applicable.
  • Page 8 PENBERTHY MODEL MGS-314 SERIES AND MGS-314D SERIES LEVEL CONTROL SWITCH INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS - APPENDIX B Figure 6 TWO WIRE ENTITY CONTROL DRAWING HAZARDOUS AREA NON-HAZARDOUS AREA Use suitably certified safety barriers for Ex ia IIC. MODEL MGS-314-A INTRINSINC SAFETY Unused NO or NC lead shall be blind MGS-314L-A...
  • Page 9: Model Kfa5-Sr2-Ex2.W.ir Interval Relay

    VCIOM-03387 © 2019, 2020 Emerson Electric Co. All rights reserved 06/20. Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners.