Error Messages - Compac Master Installation And Setup Instructions

Table of Contents

Advertisement

Error Messages

15.
Error Code
Err 3
Err 7
Err 8
Err 9
Err 10
Err 12
Ped
Abd
\\Cilaklfs1\shrdata\Masters\Installation Sheets\Master & Premier\MR160P Installation
Fault
No price or pump number set.
Excess flow.
Excess reverse rotation of encoder.
Faulty or disconnected meter encoder.
Configuration Lost
C4000 memory failure.
Display error
Sheet.doc
Page 15 of 18
Action
Set the pump number or:
Set a price at the pump or at
the controller.
Max Flowrate exceeded
Check product is not flowing
back into the tank once the
delivery has finished.
1.
Check that encoder is
plugged in.
2.
Replace encoder PCB on
meter
Reconfigure C4000 refer to
C4000 manual
Change memory IC.
F-AD-DS1225 (not applicable
to Futra)
1.
Check display cable for
loose wires/crimps
2.
Replace display PCB